Kaiyi BR380JG-1E0 — H-16 THE PRIMARY CONVEYOR AND THE SIDE CONVEYOR DO NOT MOVE UP AND DOWN

SEN02306-01 40 Troubleshooting H-16 The primary conveyor and the side conveyor do not move up and down 1 20 BR380JG-1E0 Trouble • The primary conveyor and the side conveyor do not move up and down. Relative information • Carry out the following troubleshooting when the travel system and other work equipment are nor- mal. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of acces- sory EPC valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. aCarry out troubleshooting in the WORK mode. Operation EPC valve output pressure Turn conveyor elevator switch ON Min. 2.5 MPa {Min.

26 kg/cm2} 2 Malfunction of acces- sory control valve (spool) The accessory control valve spool may have a malfunction. Check it directly. 3 Malfunction of con- veyor elevator solenoid valve The conveyor elevator solenoid valve may have a malfunction. Check it directly. 4 1) Short circuit in con- veyor elevator switch system 2) Disconnection or short circuit in accessory EPC valve 1) Carry out troubleshooting according to failure code [7REAKB]. 2) Carry out troubleshooting according to failure codes [7RFLKA], [7RFLKB], [7RFLKY].