Kaiyi BR380JG-1E0 — H-22 THE CRUSHER CLEARANCE CANNOT BE ADJUSTED

40 Troubleshooting SEN02306-01 H-22 The crusher clearance cannot be adjusted 1 BR380JG-1E0 27 Trouble • The crusher clearance cannot be adjusted. Relative information • Carry out the following troubleshooting when no foreign matter is caught between the fixed jaw and swing jaw of the crusher. • Before carrying out the troubleshooting, set the mode selector switch in the INSPECTION mode. • Carry out the following troubleshooting when the travel system and other work equipment are nor- mal.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of lock cylinder extension/ retraction solenoid valve The lock cylinder extension/retraction solenoid valve may have a malfunc- tion. Check it directly. 2 Malfunction of lock cyl- inder reset solenoid valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. Operation Solenoid valve output pressure Turn crusher clearance open or close switch on monitor ON 2.84 – 3.43 MPa {29 – 35 kg/cm2} 3 Malfunction of lock cyl- inder reset control valve (spool) The lock cylinder reset control valve spool may have a malfunction.

Check it directly. 4 Malfunction of pressure compensation valve or pressure compensa- tion piston The pressure compensation valve or pressure compensation piston of the control valve may have a malfunction. Check them directly. 5 Malfunction of lock cyl- inder reset suction valve The suction valve of the lock cylinder reset control valve may have a mal- function. Check it directly. 6 Malfunction of lock cyl- inder The lock cylinder may have a malfunction. Check it directly.

7 1) Communication error 2) Short circuit in lock cylinder extension relay system 3) Short circuit in lock cylinder retraction relay system 4) Disconnection or short circuit in lock cylinder reset sole- noid valve system 1) Carry out troubleshooting according to failure code [DAFRMC]. 2) Carry out troubleshooting according to failure codes [7RFPKB] and [7RFPKY]. 3) Carry out troubleshooting according to failure codes [7RFKKB] and [7RFKKY]. 4) Carry out troubleshooting according to failure codes [7RFNKA], [7RFNKB], [7RFNKY].