SEN02306-01 40 Troubleshooting H-20 The travel motor does not work (only one side) 1 Note 1: Disconnect the hydraulic hose and piping (travel main circuit) and install adapters to block the ends. H-21 When the travel switch of the radio controller is depressed, the machine does not travel 1 26 BR380JG-1E0 Trouble • The travel motor does not work (only one side). Relative information • Before carrying out the troubleshooting, set the mode selector switch in the TRAVEL mode.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective seal of travel control valve (suction valve) The suction valve seal of the travel control valve may be malfunction. Check it directly. 2 Defective seal of travel motor (safety valve) The safety valve seal of the travel motor may be malfunction. Check it directly. aMotors of same type on forward and reverse sides or on right and left sides may be checked by replacing the valves with each other and see- ing change of condition. 3 Defective seal of travel motor (check valve) The check valve seal of the travel motor may be malfunction. Check it directly.
aMotors of same type on forward and reverse sides or on right and left sides may be checked by replacing the valves with each other and see- ing change of condition. 4 Malfunction of travel motor (parking brake) Parking brake of travel motor may have malfunction. Check it directly. 5 Defective travel motor aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. Travel lever Leakage from travel motor Relieve travel circuit. (Note 1) Max. 27.2 l/min 6 Defective final drive The final drive may have a defect in it. Check it directly. aYou may check the final drive by abnormal sound, abnormal heating, metal powder in drain oil, etc.
Trouble • When the travel switch of the radio controller is depressed, the machine does not travel Relative information • Carry out the following troubleshooting when the machine travels when the travel lever is operated. • Before carrying out the troubleshooting, set the mode selector switch in the TRAVEL mode. • Before carrying out the troubleshooting, turn the radio control selector switch ON (RADIO CON- TROL position). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of radio control travel solenoid aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting.
Operation Solenoid valve output pressure Turn radio control travel switch ON (each position). 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of shuttle valve The shuttle valve may have a malfunction. Check it directly. 3 Disconnection or short circuit in travel solenoid system The travel solenoid system may have a short circuit or disconnection. Check it directly.