SEN01351-00 10 Structure, function and maintenance standard 1. LS valve PA : Pump port PDP : Drain port PLP : LS control pressure output port PLS : LS pressure input port PP : Pump port PPL : Control pressure input port PSIG : LS mode selector pilot port 1. Sleeve 2. Piston 3. Spool 4. Spring 5. Sheet 6. Sleeve 7. Plug 8. Locknut Function q The LS (load sensing) valve detects the load and controls the discharge amount. q This valve controls pump delivery (Q) according to differential pressure ( d PLS)[= PP – PLS] , called the LS differential pressure (the differ- ence between pump discharge pressure PP and control valve outlet port pressure PLS).
q Pump discharge pressure (PP), pressure (PLS) (called the LS pressure) coming from the control valve output, and pressure (PSIG) (called the LS selector pressure) from the pro- portional solenoid valve enter this valve. q The relationship between the LS differential pressure between the pump discharge pres- sure (PP) and LS pressure (PLS) ( d PLS) [= (PP) (PLS)] and pump delivery (Q) changes as shown in the diagram according to LS selector current (ISIG) of the LS-EPC valve. q If (ISIG) changes from 0 to 1A, setting force the spring changes, too. As the result, the specified median of the pump delivery volume switching point changes as shown in the dia- gram.
It will change in the range of 0.69 to 2.2 MPa {in the range of 7 to 22 kg/cm 2 }. 10 BR380JG-1E0