Kaiyi BR380JG-1E0 — HYDRAULIC PUMP

10 Structure, function and maintenance standard SEN01351-00 Operation 1) When the control valve is situated at neutral q The LS valve is a 3-way selector valve, with pressure (PLS) (LS pressure) from the outlet port of the control valve brought to spring chamber (B), and main pump discharge pres- sure (PP) brought to port (H) of sleeve (8). q Spool (6) is pushed to the right, and port (C) and port (D) will be connected. q Pump pressure (PP) is conducted to the larger diameter end from the port (K). q The same pump pressure (PP) is conducted to the smaller diameter end from the port (J).

q Magnitude of the force resulting from this LS pressure (PLS), force of spring (4) and the pump delivery pressure (self pressure) (PP) determine the position of spool (6). q According to the difference in the areas on servo piston (12), the pressure moves in such that the swash plate angle may be minimized. q However, magnitude of the output pressure (PSIG) (called the LS selector pressure) of the EPC valve for the LS valve entering port (G) also changes the position of spool (6). (Setting force of the spring is changed) q Before the engine is started, servo piston (12) is pushed to the left.

(See the figure) q If the control lever is at the neutral position when the engine is started, LS pressure (PLS) will be set to 0 MPa {0 kg/cm 2 }. (It is intercon- nected to the drain circuit via the control valve spool) BR380JG-1E0 11