Kaiyi BR380JG-1E0 — HYDRAULIC PUMP

SEN01351-00 10 Structure, function and maintenance standard 2) Action for the direction of maximizing the pump delivery q When the difference between pump discharge pressure (PP) and LS pressure (PLS), in other words, LS differential pressure ( d PLS) becomes smaller (for example, when the area of opening of the control valve becomes larger and pump pressure PP drops), spool (6) is pushed to the left by the combined force of LS pressure (PLS) and the force of spring (4). q If the output pressure of the EPC valve for the LS valve enters port (G), rightward force is generated on piston (7).

q If piston (7) is pushed to the right, setting force of spring (4) is weakened, changing the LS dif- ferential pressure ( d PLS) [Difference between oil pressures (PLS) and (PP)] when ports (D) and (E) of spool (6) are connected. q When spool (6) moves, port (D) and port (E) are interconnected and connected to the PC valve. q The PC valve is connected to the drain port, so the pressure across circuits (D) and (K) becomes drain pressure (PT).

(The operation of the PC valve is explained later.) q The pressure at the large diameter end of servo piston (12) becomes drain pressure (PT), and pump pressure (PP) enters port (J) at the small diameter end, so servo piston (12) is pushed to the left side. Therefore, the swash plate is moved in the direction to make the dis- charge amount larger. 12 BR380JG-1E0