beckhoff TwinCAT 2 Motion — 2.3 Group Errors

Overview of NC Errors NC Errorcodes 16 Version: 1.1 Error(Hex) Error(Dec) Error type Description The group does not have a channel, or the channel address has not been initialized. 420C 16908 Address Axis address (master axis) The group does not have a master axis (or axes) or the axis address(es) has (have) not been initialized. 420D 16909 Address Master axis address A master/slave coupling is to be inserted into the group, but there is no valid address for the leading master axis. 420E 16910 Address Slave axis address A master/slave coupling is to be inserted into the group, but there is no valid address for the slave axis.

420F 16911 Address Slave setpoint generator address A master/slave coupling is to be inserted into the group, but there is no valid address for the slave setpoint generator. 4210 16912 Address Encoder address An axis in the group does not have an encoder, or the encoder address has not been initialized. 4211 16913 Address Controller address An axis in the group does not have a controller, or the controller address has not been initialized. 4212 16914 Address Drive address An axis in the group does not have a drive, or the drive address has not been initialized. 4213 16915 Address Master setpoint generator address A group (e.g.

FIFO group) does not have a master setpoint generator or the setpoint generator address has not been initialized. There may not be enough memory available. 4214 16916 Address Axis interface NC to PLC address Group/axis does not have an axis interface from the NC to the PLC, or the axis interface address has not been initialized. 4215 16917 Address Slave axis address An existing master/slave coupling is to be removed from the group, but there is no valid address for the slave axis. 4216 16918 Address Table unknown The table, respectively the table ID, is unknown. This table is used for the master/slave coupling or for the characteristic curve.

4217 16919 Address NcControl address The NcControl address has not been initialized. 4218 16920 Initialization Command lock because persistent NC data is waiting to be transferred Axis is blocked for commands while waiting for valid I/O data to accept the queued persistent NC data. 4219 16921 Function The scaling mode MASTER-AUTOOFFSET is invalid because no reference table was found The scaling mode MASTER-AUTOOFFSET used is invalid in this context because no reference to an existing reference table can be established. This error can occur, for example, when tables are added if no unique reference to an existing reference table can be established (e.g.

because the reference is not unique, etc.).