Overview of NC Errors NC Errorcodes 18 Version: 1.1 Error(Hex) Error(Dec) Error type Description The axis enables for the master axis needed for positioning are not present. This can involve the controller enable and/ or the relevant, direction-dependent feed enable (see axis interface PlcToNc). 4224 16932 Monitoring Travel path smaller than one encoder increment (internal error) The travel path that a group/axis is supposed to move is smaller than the physical significance of one encoder increment. In other words the movement is smaller than the scaling factor of the axis. The reaction to this is that the axis is reported as having logically finished without having actively moved.
This means that an external error is not generated for the user. This error is also issued for rapid/slow traverse axes if a looping distance with nonzero parameters is smaller than the sum of the creeping and braking distances. In such a case it is not meaningful to either exceed or to fail to reach the target position. 4225 16933 Monitoring Drive hardware not ready to operate at axis start During an axis start it is ascertained that the drive hardware is not ready to operate. This can be caused by the following reasons: - the drive is in error state (hardware error) - the drive is in the start-up phase (e.g.
after an axis reset preceded by a hardware error) - the drive lacks the controller enable (ENABLE) The time required for the "start-up" of a drive after a hardware error can be in the range of several seconds. 4226 16934 Monitoring The parameters of the emergency stop are invalid. Either, both, the deceleration and the jerk are less than zero or one of the parameters is weaker than the corresponding parameter of the start data. 4227 16935 Function Setpoint generator not active The setpoint generator is inactive such that no instructions are accepted.
4228 16936 Monitoring Requested travel path/looping distance is not allowed The requested travel path or looping distance is smaller than the braking distance of the rapid/slow traverse axis. 4229 16937 Monitoring Requested target position is not allowed (slave axis) The value for the target position of a positioning task when calculated for the slave axis is not within the software end positions. In other words, it is either less than the minimum software end position or larger than the maximum software end position. This check is only carried out if the relevant end position monitoring is active.
422A 16938 Monitoring No enable for controller and/or feed (slave axis) The axis enables for one or more coupled slave axes needed for positioning are not present. This can involve the controller enable and/or the relevant, direction-dependent feed enable (see axis interface PlcToNc). 422B 16939 Parameter The activation position (position threshold) is out of range of the actual positioning The activation position (position threshold) of a new axis command (e.g. "new velocity activated at a position") is out of range. E.g. the activation position is before the actual position or behind the target position.