beckhoff TwinCAT 2 Motion — 2.3 Group Errors

Overview of NC Errors NC Errorcodes 19 Version: 1.1 Error(Hex) Error(Dec) Error type Description 422C 16940 Parameter The start or activation data of the external setpoint generation are not valid This may be caused through: 1. The external setpoint generation is active and a new activation with a start type (1: absolute, 2: relative) unequal to the current one is send. 2. The internal setpoint generation is active (e.g. PTP) and the external one is activated with the start type absolute (2 setpoint generators of the type absolute are not possible).

422D 16941 Parameter Velocity is not constant For changing the dynamic parameter 'acceleration' und 'deceleration' the axis has to be in dynamic state without acceleration and deceleration (that means constant velocity). 422E 16942 Parameter Jerk less than or equal to 0.0 is not allowed A value less than or equal to 0.0 for the jerk (PTP and CNC) is not allowed, since the jerk is by definition positive, and with a jerk of 0.0, division will generate an FPU exception.

422F 16943 Parameter Acceleration less than or equal to 0.0 is not allowed A value less than or equal to 0.0 for the acceleration (PTP and CNC) is not allowed, since the acceleration is positive by definition, and an acceleration of 0.0 will not allow a motion to be generated.

4230 16944 Parameter Absolute deceleration value less than or equal to 0.0 is not allowed A value less than or equal to 0.0 for the absolute value of the deceleration (PTP and CNC) is not allowed, since the absolute value of the deceleration is positive by definition, and an absolute value of the deceleration of 0.0 will not allow a motion to be generated 4231 16945 Parameter Target velocity less than or equal to 0.0 is not allowed A value less than or equal to 0.0 or outside the range from 10-3 up to 10+10 for the target velocity (PTP and CNC) is not allowed, since the target velocity is by definition strictly positive, and with a target velocity of 0.0, division will generate an FPU exception.

4232 16946 Monitoring Loss of resolution accuracy for requested positioning The positioning is so long in space or time that decimal places become irrelevant and inaccuracies may occur during positioning (LOSS OF PRECISION). _ _ 4233 16947 Parameter Cycle time less than or equal to 0.0 is not allowed A value less than or equal to 0.0 for the cycle time (PTP and CNC) is not allowed, since the cycle time is by definition strictly positive, and with a cycle time of 0.0, division will generate an FPU exception.

4234 16948 Internal PTP data type range exceeded Such extreme parameters have been supplied for the start task, the override or the new target position that the internal data type loses its precision. 4235 16949 Function PTP LHL velocity profile cannot be generated (internal error) Such extreme parameters have been supplied for the start task, the override or the new target position that it is not possible to generate a velocity profile of the type LHL (Low- High-Low).