Overview of NC Errors NC Errorcodes 26 Version: 1.1 Error(Hex) Error(Dec) Error type Description 427F 17023 Monitoring The new target position either has been overrun or will be overrun The new target position either has been overrun or will be overrun, since until there it is impossible to stop. An internal stop command is commended. 4280 17024 Monitoring Group not ready / group not ready for new task" (internal error / information) The group is being given a new task while it is still in the process of executing an existing task. This request is not allowed because it would interrupt the execution of the previous task.
The new task could, for instance, be a positioning command, or the "set actual position" function. Precisely the converse relationships apply for the "set new end position" function. In that case, the group/axis must still be actively moving in order to be able to cause a change in the end position. 4281 17025 Parameter Parameters of the oriented stop (O-Stop) are not allowed The modulo target position must not be lower than zero and not greater than or equal to the encoder modulo period (e.g. in the interval [0.0,360.0) ). Even in case of an error, the axis is stopped safely, but then it is not at the desired oriented position afterwards.
4282 17026 Monitoring The modulo target position of the modulo-start is invalid. The modulo target position is outside of the valid parameter range. So the position value should not be lower than zero and not greater or equal than the encoder modulo-period (e. g. in the interval [0.0,360.0] for the modulo start type "SHORTEST WAY (261)"). _ 4283 17027 Parameter The activation mode is not allowed The activation mode may have been used for online modification, scaling, as well as for online modification of the motion function. However, the activation mode used is not valid in this context.
Either the mode is not defined or not yet implemented or it cannot be implemented in this constellation (e.g. if linear tables with an illegal cyclic activation mode NEXTCYCLE or NEXTCYCLEONCE are used). In other cases the mode is valid in principle, but the command cannot be implemented because the function already executes a job. 4284 17028 Parameter The parameterized jerk rate is not allowed The jerk rate is smaller than the minimum jerk rate. The minimum jerk rate is 1.0 (e.g. mm/s^3). 4285 17029 Parameter The parameterized acceleration or deceleration is not permitted. The parameterized acceleration or deceleration is lower than the permitted minimum acceleration.
The value for minimum acceleration is calculated from minimum jerk rate and NC cycle time (minimum jerk rate multiplied with NC cycle time). The unit for example is mm/s^2. 4286 17030 Parameter The parameterized velocity is not permitted.