Overview of NC Errors NC Errorcodes 39 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4325 17189 Parameter Target window range not allowed The value for the target window is not allowed. Value range: [0.0, 10000.0] Unit: e.g. mm 4326 17190 Parameter Position window range not allowed The value for the position window is not allowed. Value range: [0.0, 10000.0] Unit: e.g. mm 4327 17191 Parameter Position window monitoring time not allowed The value for the position window monitoring time is not allowed. Value range: [0.0, 600.0] Unit: s 4328 17192 Parameter Looping distance not allowed The value for the looping distance is not allowed. Value range: [0.0, 10000.0] Unit: e.g.
mm 4329 17193 Parameter Axis cycle time not allowed The value for the axis cycle time is not allowed. Value range: [0.001, 0.1] Unit: s 432A 17194 Parameter Operation mode stepper motor not allowed The value for the stepper motor operating mode is not allowed. Value range: [1, 2] Unit: 1 432B 17195 Parameter Displacement per stepper motor step not allowed The value for the displacement associated with one step of the stepper motor is not allowed (step scaling). Value range: [0.000001, 1000.0] Unit: e.g. mm/ STEP 432C 17196 Parameter Minimum velocity for stepper motor set value profile not allowed The value for the minimum velocity of the stepper motor velocity profile is not allowed.
Value range: [0.0, 1000.0] Unit: e.g. m/min 432D 17197 Parameter Stepper motor stages for one velocity level not allowed The value for the number of steps for each velocity level in the setpoint generation is not allowed. Value range: [0, 100] Unit: 1 432E 17198 Parameter DWORD for the interpretation of the axis units not allowed The value that contains the flags for the interpretation of the position and velocity units is not allowed. Value range: [0, 0xFFFFFFFF] Unit: 1 432F 17199 Parameter Maximum velocity not allowed The value for the maximum permitted velocity is not allowed. Value range: [0.0, 10000.0] Unit: e.g.
m/min 4330 17200 Parameter Motion monitoring window not allowed The value for the motion monitoring window is not allowed. Value range: [0.0, 10000.0] Unit: e.g. mm