beckhoff TwinCAT 2 Motion — 2.5 Encoder Errors

Overview of NC Errors 2.5 Encoder Errors NC Errorcodes 44 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4400 17408 Parameter Encoder ID not allowed The value for the encoder ID is not allowed, e.g. because it has already been assigned, is less than or equal to zero, or is bigger than 255. Value range: [1 ... 255] Unit: 1 4401 17409 Parameter Encoder type not allowed The value for the encoder type is unacceptable because it is not defined. Type 1: Simulation (incremental) Type 2: M3000 (24 bit absolute) Type 3: M31x0 (24 bit incremental) Type 4: KL5101 (16 bit incremental) Type 5: KL5001 (24 bit absolute SSI) Type 6: KL5051 (16 bit BISSI) Value range: [1 ... 6] Unit:

1 4402 17410 Parameter Encoder mode The value for the encoder mode (operation mode) is invalid. Mode 1: Determination of actual position Mode 2: Determination of actual position and actual velocity (filter) Value range: [1, 2] Unit: 1 4403 17411 Parameter Encoder count direction The flag for the encoder counting direction is not allowed. Flag 0: Positive encoder count direction Flag 1: Negative encoder count direction Value range: [0, 1] Unit: 1 4404 17412 Initialization Calibration state The flag for the calibration state is not allowed. Flag 0: Axis is not referenced Flag 1: Axis is referenced Value range: [0, 1] Unit:

1 4405 17413 Parameter Encoder increments for each physical encoder rotation The value for the number of encoder increments for each physical rotation of the encoder is not allowed. This value is used by the software for the calculation of encoder overruns and underruns. Value range: [255, 0xFFFFFFFF] Unit: INC