Overview of NC Errors 2 Overview of NC Errors 2.1 General NC Errors NC Errorcodes 8 Version: 1.1 Error code ( hex ) Description 0x4000 - 0x4FFF: NC error code range 0x40nn General errors [} 8] 0x41nn Channel Errors [} 10] 0x42nn Group Errors [} 14] 0x43nn Axis Errors [} 36] 0x44nn Encoder Errors [} 44] 0x45nn Controller Errors [} 53] 0x46nn Drive Errors [} 60] 0x4Ann Table Errors [} 66] 0x4Bnn NC PLC errors [} 69] 0x4Cnn Kinematic Transformation [} 76] 0x8000 … 0x8FFF:
New extended NC error code range 0x81nn - 0x811F Bode plot (diagnosis) 0x8120 - 0x8FFF further errors [} 79] Error(Hex) Error(Dec) Error type Description 4000 16384 Internal Internal error Internal system error in the NC on ring 0, no further details. 4001 16385 Memory Memory error The ring-0 memory management is not providing the required memory. This is usually a result of another error, as a result of which the controller will halt normal operation (now if not before). 4002 16386 Internal NC retain data error (persistent data) An error occurred when loading the NC Retain data, so that the affected axes are no longer referenced (status bit "Homed" is FALSE).
This error can have the following reasons: - no NC Retain data were found - only old NC Retain data were found (old backup data set) - the NC Retain data are corrupt or inconsistent 4003 16387 Parameter Parameter for monitoring the NC setpoint output is invalid The parameter for activating or deactivating the function "cyclic monitoring of NC setpoint output for steadiness and consistency" is invalid. (Special function) 4004 16388 Internal External error This error code can be set by an external module (e.g. third-party module) or can be set if an external module has an error.
4010 16400 Parameter Channel identifier not allowed Either an unacceptable value (not 1...255) has been used, or a channel that does not exist in the system has been named.