Blue Smart IP67 Charger 4.5. Estimating charge time The time required to recharge a battery to 100% SOC (state of charge) is dependant on the battery capacity, the depth of discharge, the charge current and the battery type/chemistry, which has a significant effect on the charge characteristics. 4.5.1. Lead-acid based chemistry The bulk stage duration T bulk can be calculated as T bulk = Ah / I , where I is the charge current (excluding any loads) and Ah is the depleted battery capacity below 80% SOC. A lead-acid battery is normally at approximately 80% state of charge (SOC) when the bulk charge stage is completed.
The absorption stage duration T abs will vary depending on the depth of discharge; up to 8 hours of absorption may be required for a deeply discharged battery to reach 100% SOC. For example, the time required to recharge a fully discharged Lead-acid based 100Ah battery with a 10A charger would be approximately: Bulk stage duration, T bulk = 100Ah x 80% / 10A = 8 hours Absorption stage duration, T abs = 8 hours Total charge duration, T total = T bulk + T abs = 8 + 8 = 16 hours 4.5.2. Li-ion based chemistry A Li-ion based battery is normally well above 95% state of charge (SOC) when the bulk charge stage is completed.
The bulk stage duration T bulk can be calculated as T bulk = Ah / I , where I is the charge current (excluding any loads) and Ah is the depleted battery capacity below 95% SOC. The absorption stage duration T abs required to reach 100% SOC is typically less than 30 minutes. For example, the charge time of a fully discharged 100Ah battery when charged with a 10A charger to approximately 95% SOC is T bulk = 100 x 95% / 10 = 9.5 hours. For example, the time required to recharge a fully discharged Li-ion based 100Ah battery with a 10A charger would be approximately:
Bulk stage duration, T bulk = 100Ah x 95% / 10A = 9.5 hours Absorption stage duration, T abs = 0.5 hours Total charge duration, T total = T bulk + T abs = 9.5 + 0.5 = 10 hours Page 11 Operation