IP67 Charger — 8.2. Expert mode settings

Blue Smart IP67 Charger To access the expert mode settings: 1. Open the Advanced setting page and enable User defined configuration - see the 'Advanced configuration > Advanced settings' section for instructions. 2. Toggle the Expert mod e switch on to enable additional Expert mode settings (extension of the Advanced settings menu). 3. Read the warning message and then select OK to proceed. 4. The Expert mode settings (extension of the Advanced settings menu) will now be accessible. The ADDITIONAL expert mode settings include: A. Charge voltage i. BatterySafe The BatterySafe setting allows the BatterySafe voltage control to be enabled or disabled.

When BatterySafe is enabled, the rate of battery voltage increase during bulk stage is automatically restricted to a safe level. In cases where the battery voltage would otherwise increase at a faster rate, the charge current is reduced to prevent excessive gassing. B. Bulk i. Bulk time limit The bulk time limit setting restricts the maximum time the charger can spend in bulk stage as a protection measure, since the absorption voltage should have been achieved by this time. If the bulk time limit is satisfied the charger will move directly to float stage. ii. Re-bulk current The re-bulk current setting is the charge current limit that will trigger a new charge cycle.

If the charge current exceeds the re-bulk current threshold for four seconds while the charger is in float or storage stage, the charger to move back into bulk charge stage. Note that even when the re-bulk setting is disabled, re-bulk will still occur if the charge current is maintained at the maximum charge current for four seconds while the charger is in float or storage stage. C. Absorption i. Absorption duration The absorption duration setting allows selection between adaptive absorption time (calculated based on the bulk time / level of discharge) or a fixed absorption time. ii.

Maximum absorption time / Absorption time The maximum absorption time / absorption time setting enables the maximum adaptive absorption time or the fixed absorption time to be configured (depending if adaptive or fixed absorption time is selected). Note that regardless if adaptive or fixed absorption time is selected, the absorption phase can end early based on the tail current setting (if enabled). iii. Tail current Page 60 Advanced Configuration