IP67 Charger — 8.2. Expert mode settings

Blue Smart IP67 Charger The tail current setting enables the absorption stage to be ended early based on charge current. If the charge current drops below the tail current threshold for one minute, the absorption stage will immediately end and the charger will move to float or storage stage. iv. Repeated absorption The repeated absorption setting enables the elapsed time between each automatic refresh charge cycle (1h in absorption stage) to be configured. Repeated absorption is enabled by default and can be disabled which results in the battery staying in storage mode indefinitely. D. Recondition i.

Recondition stop mode The recondition stop mode setting allows selection between the recondition stage being ended upon the battery voltage reaching the recondition stage voltage setpoint or a fixed time period. ii. Maximum recondition duration The recondition time setting enables the maximum recondition time or the fixed recondition time to be configured (depending on the recondition stop mode selected). Page 61 Advanced Configuration