Jun.

2011 BF-3(T) SERVICE NOTES Issued by RJA Table of Contents Identifying the BF-3(T) .....................................................2 Cautionary Notes ..............................................................2 Specifications .....................................................................3 Location of Controls .........................................................4 Exploded View ..................................................................5 Disassembly Procedure....................................................6 Conversion to the BF-3A..................................................6 Parts List.............................................................................7 Verifying the Version........................................................9 Data Backup and Restore Operations ............................9 Performing a Factory Reset..............................................9 Updating the System ........................................................9 Test Mode...........................................................................9 Circuit Board (Main, VR, LED, SW, Output B Board)................................................................................12 Circuit Diagram (Main, VR, LED, SW, Output B Board)................................................................................14 Copyright © 2011 Roland Corporation All rights reserved.

No part of this publication may be reproduced in any form without the written permission of Roland Corporation. CC-KWS 17058043E1

Стр. 1

Cautionary Notes

Jun. 2011 BF-3(T) Identifying the BF-3(T) Cautionary Notes The BF-3(T) exists in two types that have different circuit structures. In this Service Notes, the older type is called the BF-3 , and the newer type is called the BF-3A . Both have Flanger BF-3 inscribed on the pedal and appear at a glance to be completely identical, but they can be distinguished as indicated in the following table. Before beginning the procedure, please read through this document. The matters described may differ according to the model.

User Data Cannot Be Backed Up The setting for the sleep mode is saved on the Main Board even when the power has been switched off, but neither verification of its status (ON or OFF) nor backing up the setting is possible. When the Main Board has been replaced, the sleep mode is returned to its default (ON). For more information about the sleep mode, refer to About Sleep Mode (Owner’s Manual, p. 14). After identifying the type of the product being serviced, refer to the corresponding Service Notes for information on required parts and test methods. No user data other than the setting for the sleep mode is saved. BF-3: SERVICE NOTES (#17058043E0) BF-3A:

SERVICE NOTES 2ND EDITION (#17058043E1) Part Replacement This version of Service Notes is for the BF-3A. When replacing components near the power-supply circuit or a heat- generating circuit (such as a circuit provided with a heat sink or including a cement resistor), carry out the procedure according to the instructions with respect to the part number, direction, and attachment position (mounting so as to leave an air gap between the component and the circuit board, etc.). Parts List A component whose part code is ******** will not be supplied as a service part because one of the following reasons applies. • Because it is supplied as an assembled part (under a different part code).

• Because a number of circuit boards are grouped together and supplied as a single circuit board (under a different part code). • Because supply is prohibited due to copyright restrictions. • Because reissuance is restricted. • Because the part is made to order (at current market price). • Because it is carried in electronic data on the Roland web site. • Because it is a package or an accessory irrelevant to the function maintenance of the main body. • Because it can be replaced with an article on the market.

(battery or etc.) Circuit Diagram In the circuit diagram, “NIU” is an abbreviation for “Not in Use,” and “UnPop” is an abbreviation for “Unpopulated.” They both mean non-mounted components. The circuit board and circuit board diagram show silk-screened indications, but no components are mounted. 2 BF-3 BF-3A Production number Up through H**8559 H**8560 and after Style of component mounting on the circuit board Single-side mounting Double-side mounting System version Version 1.00 Version 2.00 or later

Стр. 2

Specifications

Jun. 2011 BF-3(T) Specifications BF-3: Flanger (BF-3A) Nominal Input Level Power Supply -20 dBu DC 9 V; Dry battery 6F22 (9 V) type (carbon)/Dry battery 6LR61 (9 V) type (alkaline) Input Impedance AC Adaptor (PSA-series: optional) 1 M Ω Current Draw Nominal Output Level 40 mA (DC 9 V) -20 dBu * Expected battery life under continuous use: Carbon: 3 hours Output Impedance Alkaline: 10 hours These figures will vary depending on the actual conditions of use.

1 k Ω Dimensions Recommended Load Impedance 73 (W) x 129 (D) x 59 (H) mm 10 k Ω or greater 2-7/8 (W) x 5-1/8 (D) x 2-3/8 (H) inches Delay Time Weight 0.3 mS–14.4 mS (GUITAR IN) 435 g /1 lb (including Battery) 0.3 mS–6.3 mS (BASS IN) Accessories LFO Speed Owner’s Manual (#5100021063) 100 mS–18 S Leaflet (“USING THE UNIT SAFELY,” “IMPORTANT NOTES,” and “Information”) (#********) Residual Noise Dry battery/9 V type (6F22) (#********) * The battery that was supplied with the unit is for temporary use intended primarily for testing its operation.

-95 dBu (IHF-A Typ.) Controls Options Pedal Switch AC Adaptor PSA-series MANUAL Knob RES (resonance) Knob DEPTH Knob RATE Knob MODE Knob * 0 dBu = 0.775 Vrms Indicator * Printed matters will not be supplied after the end of the production. Then, download the electronic file from the Roland web site. CHECK Indicator (Serves also as tempo and battery check indicator) * In the interest of product improvement, the specifications and/or appearance of this unit are subject to change without prior notice. Connectors GUITAR IN Jack BASS IN Jack OUTPUT A (MONO) Jack OUTPUT B Jack AC adaptor Jack (DC 9 V) 3

Стр. 3

Location of Controls

Jun. 2011 BF-3(T) Location of Controls fig.panel.eps 16 17 18 4 No.

Part Code Part Name Description Q’ty 1 5100014487 COMPACT PSA LABEL (22537538R0) 1 2 5100021036 PANEL 1 3 5100021031 CASE 1 4 22480220 P R-KNOB (INTERNAL) (SS) BF BLK/LCG 1 22480221 P O-KNOB (EXTERNAL) (OUTER) S BLK/LCG 1 5100018911 ROTARY POT(F3229220R0) RD912DF-20-20FWH-B50K-60009A2 1 40128923 HEX NUT M7 1 5 5100001341 6.5MM JACK HTJ-064-12DMP (13449150R1) 1 5100003926 PLAIN WASHER 9X13.5X0.5T NI(H5039158R0) 1 5100008086 INT TOOTH WASHER 9.5X12.5X0.5 NI RTC(H5039205R0) 1 5100003918 JACK NUT M9X12X2 NI RTC(H5039510R0) 1 5100015893 PLAIN WASHER 9.2X14X1.6 NI (H5039104R0) 1 5100015900 PLAIN WASHER 9.6X14XW11X1.0 AL (22137709R0) 1 6 13449105R0 6.5MM JACK HTJ-064-14I 1 5100003926 PLAIN WASHER 9X13.5X0.5T NI(H5039158R0) 1 5100008086 INT TOOTH WASHER 9.5X12.5X0.5 NI RTC(H5039205R0) 1 5100003918 JACK NUT M9X12X2 NI RTC(H5039510R0) 1 7 5100008294 PEDAL PLATE (22357304R0) 1 8 5100006632 BOTTOM COVER (22027851R0) 1 9 5100006633 BOTTOM FOOT (22357305R0) 1 10 5100006631 CAUTION SEAL PSA (FCC/EMI)(G2537516R2) 1 11 5100007512 THUMB SCREW (H5029820R0) 1 12 F3439875R0 ADAPTOR JACK KM02018ABM1P 1 13 F5029423R0 LED L-3VEGW 1 5100002339 LED SPACER 304 1 14 04567601 P R-KNOB MF BLK/LCG(22480260R0) 1 5100014193 R.POTENTIOMETER (F3279853R0) RD901F-20-15FB-B50K-04 1 40128923 HEX NUT M7 1 15 04567601 P R-KNOB MF BLK/LCG(22480260R0) 2 F3279852R0 POTENTIOMETER RD901-20-15FW-B54-006 2 40128923 HEX NUT M7 2 16 5100020609 6.5MM JACK SCJ614M2NCS3B11G 1 5100003926 PLAIN WASHER 9X13.5X0.5T NI(H5039158R0) 1 5100008086 INT TOOTH WASHER 9.5X12.5X0.5 NI RTC(H5039205R0) 1 5100003918 JACK NUT M9X12X2 NI RTC(H5039510R0) 1 17 5100006457 6.5MM JACK HTJ-064-14D(13449140R0) 1 5100003926 PLAIN WASHER 9X13.5X0.5T NI(H5039158R0) 1 5100008086 INT TOOTH WASHER 9.5X12.5X0.5 NI RTC(H5039205R0) 1 5100003918 JACK NUT M9X12X2 NI RTC(H5039510R0) 1 18 5100021035 PEDAL 1