omron — 4.2 Connectors on eMB-40M Interface Panel

4.2 Connectors on eMB-40M Interface Panel 4.2 Connectors on eMB-40M Interface Panel A B I C H D E F Figure 4-2. eMB-40M Interface Panel See the following table for descriptions of the interface panel connectors. Table 4-1. Connectors on the eMB-40M Interface Panel 28 Cobra 450, 500, and 650 User's Guide 19148-000 Rev. E G Key Name Meaning A XSYSTEM Connects to the eAIB XSYSTEM cable or the eAIB XSYS cable (SmartController EX). B Ground Point For cable shield from user-supplied 24 VDC cable. C +24 V Pin +24 V pin of the 24 VDC connector. D 24 VDC For user-supplied 24 VDC power. The mating connector is provided. E 200/240 VAC For 200-240 VAC, single-phase, input power.

The mating connector is provided. F XIO For user I/O signals for peripheral devices. Provides 8 out- puts and 12 inputs. See Connecting Digital I/O to the Sys- tem on page 31 for connector pin allocations for inputs and outputs. That section also contains details on how to access these I/O signals. (DB-26, high density, female) G XBELTIO Adds two belt encoders, EXPIO, and an RS-232 interface, which is reserved for future use. H Smart-Servo For the IEEE 1394 cable from the controller I ENET Two Ethernet ports are available. One will be needed to connect to a PC running ACE software.