Data Transfer Sequence Interface timing Figure D-4 shows the timing for the parallel interface. BUSY ACKNLG DATA STROBE Approx. 5µs 0.5 µs (min.) 0.5 µs (min.) 0.5 µs (min.) Figure D-4. Parallel interface timing Signal relationships Table D-3 shows the way data entry is handled in the on-line and off- line states by showing the relationships between seven signal sets. Table D-3. Signal interrelations *When SLCT IN is at high level, data entry is enabled, but the input data will be disregarded until SLCT IN is at low level. Note: ERROR status is assumed to rest only in off-line state, and the ERROR status does not always mean SLCT IN.
0-) On-Line SLCTIN ERROR BUSY ACKNLG DATA ENTRY OFF HIGH.ILOW LOW HIGH Not generated Disabled ON HIGH HIGH LOW/HIGH Generated after data entiy Enabled' ON LOW HIGH Same Same Enabled (nomial entty)