Delta Electronics CP2000 — CP2000 C EN 20200909 web

11 690 V Frame Size C D E Model VFD-ͥͥͥCP63A-ͥͥ 185 220 300 370 450 550 750 900 1100 1320 Output * LIGHT DUTY Rated Output Capacity (kVA) 29 36 43 54 65 80 103 124 149 179 Applicable Motor Output ( 690V, kW) 18.5 22 30 37 45 55 75 90 110 132 Applicable Motor Output ( 690V, HP) 25 30 40 50 60 75 100 125 150 175 Applicable Motor Output (575V, HP) 20 25 30 40 50 60 75 100 125 150 Rated Output Current (A) 24 30 36 45 54 67 86 104 125 150 Overload tolerance 120% of rated current for 1 minute during every 5 minutes Max.output frequency (Hz) 599.00 NORMAL DUTY Rated Output Capacity (kVA) 24 29 36 43 54 65 80 103 124 149 Applicable Motor Output ( 690V, kW) 15 18.5 22 30 37 45 55 75 90 110 Applicable Motor Output ( 690V, HP) 20 25 30 40 50 60 75 100 125 150 Applicable Motor Output (575V, HP) 15 20 25 30 40 50 60 75 100 125 Rated Output Current (A) 20 24 30 36 45 54 67 86 104 125 Overload tolerance 120% of rated current for 1 minute during every 5 minutes; 160% of rated current for 3 seconds during every 25 seconds Max.output frequency (Hz) 599.00 Carrier Frequency (kHz) 2 ~ 9 (default setting 4) Input Input Current (A) Light Duty 29 36 43 54 65 81 84 102 122 147 Input Current (A) Normal Duty 24 29 36 43 54 65 66 84 102 122 Rated Voltage / Frequency 3-Phase, 525 ~ 690 VAC ( -15% ~ +10%), 50/60 Hz Operating Voltage Range 446 ~ 759 VAC Frequency Tolerance 47 ~ 63 Hz Efficiency (%) 97 Power Factor > 0.98 AC Drive Weight (Kg) 10 ± 1.5 39 ± 1.5 61 ± 1.5 Cooling Method Fan cooling Braking Chopper Frame C (built-in) Frame D and above (optional) DC Choke Frame C (optional) Frame D and above (built-in) 690 V Frame Size F G H Model VFD-ͥͥͥCP63A-ͥͥ 1600 2000 2500 3150 4000 4500 5600 6300 Output * LIGHT DUTY Rated Output Capacity (kVA) 215 263 347 418 494.5 534.7 678.5 776 Applicable Motor Output ( 690V, kW) 160 200 250 315 400 450 560 630 Applicable Motor Output ( 690V, HP) 215 270 335 425 530 600 750 850 Applicable Motor Output (575V, HP) 150 200 250 350 400 450 500 750 Rated Output Current (A) 180 220 290 350 430 465 590 675 Overload tolerance 120% of rated current for 1 minute during every 5 minutes Max.output frequency (Hz) 599.00 NORMAL DUTY Rated Output Capacity (kVA) 179 215 239 347 402.5 442.7 534.7 776 Applicable Motor Output ( 690V, kW) 132 160 200 250 315 355 450 630 Applicable Motor Output ( 690V, HP) 175 215 270 335 425 475 600 850 Applicable Motor Output (575V, HP) 150 150 200 250 350 400 450 750 Rated Output Current (A) 150 180 220 290 350 385 465 675 Overload tolerance 120% of rated current for 1 minute during every 5 minutes; 160% of rated current for 3 seconds during every 25 seconds Max.output frequency (Hz) 599.00 Carrier Frequency (kHz) 2 ~ 9 (default setting 4) 2 ~ 9 (default setting 3) Input Input Current (A) Light Duty 178 217 292 353 454 469 595 681 Input Current (A) Normal Duty 148 178 222 292 353 388 504 681 Rated Voltage / Frequency 3-Phase, 525 ~ 690 VAC ( -15% ~ +10%), 50/60 Hz Operating Voltage Range 446 ~ 759 VAC Frequency Tolerance 47 ~ 63 Hz Efficiency (%) 97 98 Power Factor > 0.98 AC Drive Weight (Kg) 88 ± 1.5 135 ± 4 243 ± 5 Cooling Method Fan cooling Braking Chopper Frame D and above (optional) DC Choke Frame D and above (built-in) Note :

1. When a load is a surge load, use a higher level model. 2. For Frame A, B and C, Model VFDXXXCPXXX-21, the enclosure type is IP20/ UL OPEN TYPE. 3. For Frame D and above, if the last two characters of the model are 00, then the enclosure type is IP00/ IP20/ UL OPEN TYPE; if the last two characters of the model are 21, the enclosure type is IP20/NEMA1/ UL TYPE1.