Chapter3 Handling Checking the Gap Between Labels Measure the shifted distance between the tip of the last label printed from the compiled data and the actual print start position. Calculate how many millimeters each label is shifted. You can check this by using: the distance the labels have shifted / (the number of labels connected - 1). For example, if four labels are connected in one piece of data, and the fourth label is shifted by 0.6 mm (0.02 inches), you can adjust the gap between labels by 0.2 mm (0.01 inches) to eliminate the shift in all four labels.
0.6 mm (0.02 inches) / (4 labels -1) = 0.2 mm (0.01 inches) Case where the printing position is shifted to the front Case where the printing position is shifted to the back Paper feed direction Paper feed direction corrected to the correct position. 137 Measurement result Measurement result -0.6 mm (-0.02 inches) +0.6 mm (+0.02 inches) Last label printed from the compiled data Measure the distance shifted from the actual label tip. First label printed from the compiled data As the printer detects the actual label positions, this is Compil (Number o ed data f labels: 4) Compil (Number o ed data f labels: 4)