Chapter 3 Commands Acquisition commands for mode setting values for clogged nozzle detected signal (output) [Format] ~H(CNA,D [Parameter] None [Function] Acquire the mode setting values for the clogged nozzle detected signal. 3 42 Return value after executing this command Description D/0 Clogged nozzle detected signal (pin 24) OFF (not output) 1 Clogged nozzle detected signal (pin 24) set to Normal: High, When nozzle clogged: Low E/2 Clogged nozzle detected signal (pin 24) set to Normal: Low, When nozzle clogged: High When nozzle clogged:
High Acquisition commands for mode setting values for head maintenance signal (output) [Format] ~H(CNA,M [Parameter] None [Function] Acquire the mode setting values for the head maintenance signal. Return value after Description executing this command D/0 Head maintenance signal (pin 21) OFF (not output) 1 Head maintenance signal (pin 21) set to Normal: High, When head maintenance is in progress: Low E/2 Head maintenance signal (pin 21) set to Normal: Low, When head maintenance is in progress: High Return value after executing this command Description D/0 Head maintenance signal (pin 21) OFF (not output) 1 Head maintenance signal (pin 21) set to Normal: