Chapter 6 External I/F Signal Operation Mode Settings Mode Setting for Clogged Nozzle Check Signal Details are as follows. Mode Setting for Feed Signal Details are as follows. Mode Setting for Start Print Signal The settings are as follows. 6 Mode Setting for Re-print Signal Details are as follows. 58 Setting value (mode) Description Disable Ignore the clogged nozzle check signal. Enable Set the clogged nozzle check signal to the following mode: Perform a clogged nozzle check when a low pulse signal is input for 30 msec or longer. Setting value (mode) Description Disable Ignore the feed signal. Enable Set the feed signal to the following mode:
Feed paper when a low level signal is input for 30 msec or longer. Setting value (mode) Description Disable Set the start print signal to the following mode: Ignore it even if the start print signal is input. (Normal print mode in which the printer receives and prints data, without using the start print signal input to the external I/O.) Pulse mode Set the start print signal to the following mode: Print labels when a Low signal is input for 30 msec or longer. Level mode Set the start print signal to the following mode: Print labels as long as a Low signal is input. Setting value (mode) Description Disable Ignore the re-print signal. Enable Set the re-print signal to the following mode:
Reprint the previously printed label when a Low signal is input for 30 msec or longer.