EPSON — FAQ

Chapter 7 Appendix FAQ This section provides the answers to questions related to system development. 63 Questions Answer What is the feed control method for the backfeed operation? Speed control is used to feed paper for the backfeed operation. Tension control is not used. What is the speed of the backfeed operation? 300 mm/sec (12 ips) What is the length of the backfeed operation? The backfeed operation, from the specified stop position (at maximum position adjustment) to the print start position, is approximately 250 mm. With the manual backfeed button, it is approximately 500 mm. It does not depend on the length of the label. Backing paper winding specifications:

How are tension and the backfeed operation handled? Since paper jams and skewing can occur, the tension for winding the backing paper is set low, to 1 N or less. The backfeed operation draws the backing paper into the printer, so allow some room by using a buffer or dancer roll. Is there a control method that is not affected by the head capping time, in order to improve the printing speed? After printing ends, the head will be capped if the waiting for data time is 1 second (initial value) or longer. In that case, it will take longer for printing to start than if the head were not capped.

For continuous printing, throughput can be improved by transmitting the data for multiple print jobs in advance, and using the start print signal to keep the issue timing within 1 second so that printing can be performed continuously without capping the head. Please contact us for information about changing the initial value. Can electromagnetic relays and similar devices be driven directly? Solid state relays (SSR), electromagnetic relays, and similar devices can be driven directly only when used under the following conditions. • The sink current must not exceed 50 mA. • Make sure that the printer I/O power (VCC EX) and external device I/O _ power are the same voltage.

• Use a device equipped with a surge protection circuit. • The total sink current must not exceed 180 mA when all of the following conditions are satisfied. ∗ When I/O power (VCC EX) and SG are not separated _ ∗ When the I/O power (VCC EX) output from pin 9 is used for the _ external device I/O power. ∗ When using multiple output signals. If controlling by use of the printer side I/O power supply (when I/O power (VCC EX) and SG are not separated): page 17 _ If controlling by use of the external device I/O power supply (when I/O power (VCC EX) and SG are separated): page 18 _ Can the external device I/O power supply be used at 24 V?

When setting the jumper pin settings to "I/O power (VCC EX)/SG _ separated", a 24 V external device I/O power supply can be used. In this case, the input range of the external device I/O power supply is 5 to 28 V. Check the "Figure of Jumper Settings and I/O Power (VCC EX) and _ Ground Connections" and set the jumper pin settings to "I/O power (VCC EX)/SG separated" before connecting to the external device I/O _ power supply. (page 16)