Daikin 3P607381-6C (BRC1H63W/BRC1H63K remote controller) — Daikin 3P607381-6C/BRC1H63W/BRC1H63K Remote Control Manual PDF (EN)

Overview of Screens The descriptions in this section are just examples. The items available for setting vary depending on the indoor unit you are using. If there is no button operation for about 10 seconds, the screen returns to the home screen. Home screen Information screen 12:34 30 28 Press . Press and hold for 5 seconds. The list of indoor unit functions, current time, and error codes, etc. are displayed as icons. For the meaning of each icon, refer to the front side of this sheet. Use or to select , then press . Press . User menu Use or to select the icon you want to change to, then press .

You can change fundamental functions such as the operation mode, fan speed, airflow, brightness of Status indicator (LED), and Fahrenheit/Celsius display. Changing the operation mode Changing the fan speed Changing the airflow direction Use or to select the operation mode you want to change to, then press . Use or to select the fan level you want to change to, then press . Use or to select the airflow direction you want to change to, then press . Auto Heat Cool Fan Dry Auto Lv1. (L) Lv.2 Position 0 Position 1 Position 2 Position 3 Lv5. (H) Lv.4 Lv3. (M) Auto Swing Position 4 Names and Functions Depending on the connected model, some items may not be displayed.

Home screen Information screen Screen display explanation g f m a OFF • Displayed when operation is stopped. j Fahrenheit/Celsius • Depending on the setting, Fahrenheit/ Celsius display can be selected. b a 30 h q 12:34 n b Error/Filter/Test/Streamer/Zigbee icon • Error, filter, test, streamer and Zigbee icons are displayed. k Air Purifying i c OFF 28 r o : Error : Filter : Test l Set temperature • Displays setpoint temperature. d e j k p : Streamer : Zigbee m Clock (24 hours time display) l A3-01 (Unit 00) • The streamer icon is displayed when Mold Proof operation is active. n MAIN/SUB remote controller sign Icon view • The Zigbee icon will flash when sensor connection is lost.

o Status • Notifies the status. User menu c Centralized Control • Displayed when under centralized management. p Error display • If an error occurs, the icon, an error code and unit number are displayed. m q n 12:34 30 32 1050 PPM A3-01 (Unit 00) d Operation mode • Displays the current operation mode. q Information icon r Bluetooth/Zigbee icon • Bluetooth and Zigbee icons are displayed. : Bluetooth t s e Ventilation mode : Zigbee p f Room temperature • Displays the current room temperature. s Sensor values • Zigbee sensor values are displayed when normal values are received and Zigbee sensor settings have been configured.

• If Zigbee sensor values cannot be received, sensor values will be displayed as per original settings. • If there are no sensors, a horizontal bar (“–”) is displayed. Sensor view g Setback • Blinks during setback operation. • Displayed during setback setting. h Bluetooth • Indicates that the controller is communicating with a mobile device, for use with the app. i Changeover Under Control • Displayed when controller is unauthorized to select heating/cooling operation. t Settings menu icon 3P607381-6C EM22A036 [2210] HT