Chapter 3 Creating and Editing Screens Revision May, 2010 3-105 Property Description of Set Constant Buttons Trigger Trigger Type The user can use this setting to trigger the designated controller address to be ON before or after writing the setting value. Please note that this function can only trigger the controller address to be ON. If the controller address needs to be triggered again, the user should set the address to be OFF manually. Detail Range Data Length There are 16bits Word and 32bits Double Word two options. Data Format There are following data format provided: Word/Double Word 1. BCD 2. Signed BCD 3. Signed Decimal 4. Unsigned Decimal 5.
Hex Const Value Used to enter the constant value that the user wants to write. After pressing OK button, HMI will examine the value by referring to the selected data length and data format. User Security Level Use this option to set the user priority for pressing this element. Only the priority that is equal to or higher than the current setting can use this element. Set Low Security Use this option to force the current priority to be the lowest after the button is pressed. This can prevent the misoperation made by the user (operator).
InterLock Address InterLock Level When InterLock Address is set to be ON or OFF (this is determined by the property of “InterLock Level”), this button can be enabled. Before Execute Macro If this option is set, when the user presses the button, the system will execute the command of this macro first and then perform the operation of this button. But, if the state of the button is not triggered by pressing the button (via macro or external signal), the command of this macro will not be executed.