Mitsubishi — 3.8.4.1 Normal

Chapter 3 Creating and Editing Screens Revision May, 2010 3-121 Property Description of Normal Bar Elements Setting When the user has input the target value, low & high limit, and minimum & maximum value, after pressing OK button, HMI will examine the value by referring to the selected data length and data format. Data Length: There are 16bits Word and 32bits Double Word two options. Memory Format: here are following data format provided: Word/Double Word 1. BCD 2. Signed BCD 3. Signed Decimal 4. Unsigned Decimal 5. Hex Min. Value / Max. Value: Used to set the display minimum and maximum value. Target Value Color The user can decide if the target value display or not by using this option.

If this option is set, the target value and its color set by the user will display on the screen. HMI will refer to the minimum and maximum value and draw the proper reference line on the bar element just like the figure shown below: (Here we set the target value is 50 and its color is in red. The maximum and minimum value is 100 and 0 respectively.) Ranges (Enable range setting) Please refer to the description of Low & High Region Color. Variable target/range limits When the target value and low & high limit is a variable value, the low limit address is Read Address+1, the high limit address is Read Address+2 and the address of target value is Read Address+3.