Chapter 3 Creating and Editing Screens Revision May, 2010 3-123 Property Description of Differential Bar Elements Style Standard Raised Sunken Display Format Horizontal: The differential value display horizontally. Vertical: The differential value display vertically. Setting Data Length: There are 16bits Word and 32bits Double Word two options. Memory Format: here are following data format provided: Word/Double Word 1. BCD 2. Signed BCD 3. Signed Decimal 4. Unsigned Decimal 5. Hex Standard Value Used to set the standard value for calculating differential value Minimum Value Maximum Value The minimum and maximum value in the differential bar element.
Display Deviation Limit The differential limit and color can be set only when this option is selected. Also, the differential value will display in the designated color set by the user. If this option is not selected, the differential value will be displayed in the foreground color directly on the screen. Variable Standard Value/Deviation Limit When standard value and high limit of differential value is variable. The address of standard value is Read Address+1 and the address of differential limit value is Read Address+2.
When the user has input the standard value, minimum & maximum value and differential limit, after pressing OK button, HMI will examine the value by referring to the selected data length and data format.