Chapter 3 Creating and Editing Screens 3-174 Revision May, 2010 Property Description of X-Y Chart Elements Setting Vert. Read Address The address can be internal memory or the controller address. (Please refer to Table 3.2.2 Property Description of General Buttons.) The X-Y chart will continuously read numbers of addresses from the vertical read address set by the user, convert the read data into the points of Y-axis and display on HMI screen. The numbers of the addresses is determined by the setting of “Sample Number”. Sample Flag It is used to set trigger and clear flag. When sample flag is triggered, it will start to read data and draw the X-Y chart.
This sample flag is located within the control block 2. Please refer to Chapter 5 for the settings of the control block. Horiz. Minimum Horiz. Maximum It is used to set the minimum and maximum value of the horizontal display data, i.e. the minimum and maximum value of X-axis. If the read value is more the maximum or less than the minimum, the system will display the minimum and maximum value still. Vert. Minimum Vert. Maximum It is used to set the minimum and maximum value of the vertical display data, i.e. the minimum and maximum value of Y-axis. If the read value is more the maximum or less than the minimum, the system will display the minimum and maximum value still.
Line Size Used to the display line width. The range is within 1 ~ 8 and the unit is pixel. Line Color Used to set the display line color. Grid Line Color Horiz. Line Number Vert. Line Number Please refer to the figure below. The grid color is set to red and the grid numbers in horizontal and vertical direction are both set to 2. X Used to set X coordinate Y Used to set Y coordinate Width Used to set the element width Height Used to set the element height