Mitsubishi — 3.11.1 Configuration

Chapter 3 Creating and Editing Screens Revision May, 2010 3-231 COM Port tab in Configuration option Comm. Parameter Baud Rate Communication baud rate. There are 4800, 9600, 19200, 38400, 57600 and 115200 these options. The users can enter the setting value directly also but the maximum. setting value can not exceed 187500. Parity There are three options: None, Odd and Even. Ethernet Setting HMI 1. Choose Ethernet and the user can set the Ethernet setting. 2. If Overwrite IP function is enabled, HMI will update the Ethernet setting after the screen data is download. 3. If Obtain IP address automatically box is checked, HMI will get the IP address automatically.

But before enabling this function, ensure that DHCP server is connected. 4. If Obtain IP address automatically box is not checked, the user must set Ethernet setting, i.e. HMI IP address, Subnet Mask, Gateway IP, etc. manually. PLC Click the node under Etherent option and the communication parameter setting will display. Each external controller, i.e. PLC has its own communication parameter setting.