Mitsubishi — 3.11.2 Alarm Setup

Chapter 3 Creating and Editing Screens 3-240 Revision May, 2010 Alarm Setup Dialog Box Alarm Setting The calculation method of the size of the alarm frequency table is as follows: 2Bytes(a)N(b)ActualFileSizeBytes a Alarm Frequency Data b Alarm Type Example: If there are five alarm types, the required capacity for saving alarm data is: 2 Bytes × 5 = 10 Bytes Alarm Moving Sign When Alarm Moving Sign is enabled, if a fault message is detected by HMI, an alarm moving sign will show and run on the HMI. Enable Enable the alarm moving sign. Position Determine the display position of alarm moving sign. It can be Top or Bottom.

Direction Left Alarm message will move from right to left (Move to left). Right Alarm message will move from left to right (Move to right). Up Alarm message will move from bottom to top (Move to Up). Down Alarm message will move from top to bottom (Move to Down). Moving Points Set the moving points every time for the alarm moving sign. The unit is Pixel and the range is between 1 ~ 50 points. Interval (ms) Set the interval time every time for the alarm moving sign. The unit is ms and the range is between 50 – 3000 ms. Background Color Set the background color of the alarm moving sign. a Alarm Frequency Data b Alarm Type