Mitsubishi — 3.4.2 Status Block

Chapter 3 Creating and Editing Screens Table 3-4-2 Status Block Designations General Control Status Register (GCSR)  Screen Switch Status Flag When HMI switches the screen, this flag is turned ON. After the screen switch is completed, this flag is turned OFF.  Clear Status of Alarm Buffer When HMI clears the alarm buffer, this flag is turned ON. After this function is completed, this flag is turned OFF.  Clear Status of Alarm Counter When HMI clears the alarm counter, this flag is turned ON. After this function is completed, this flag is turned OFF.  User Security Level Flag Bits 8 to 10 hold the current user security level.

Revision May, 2010 3-37 Example 1 Example 2 Word Control Register (PLC register) (HMI register) Address Example Address Example 7 General Control Status Register 2 (GCSR2) Dm+7 D17 $m+7 $32 Binary Display of Relative Bit Function Position (x) 0 0000 0000 0000 000x Screen Switch Status Flag 1-2 0000 0000 0000 0xx0 Reserved 3 0000 0000 0000 x000 Clear Status of Alarm Buffer 4 0000 0000 000x 0000 Clear Status of Alarm Counter 5-7 0000 0000 xxx0 0000 Reserved 8 0000 000x 0000 0000 User Security Level Flag (Level 1) 9 0000 00x0 0000 0000 User Security Level Flag (Level 2) 10 0000 0x00 0000 0000 User Security Level Flag (Level 4) 11-15 xxxx x000 0000 0000 Reserved Flag Control Level Binary Display ON Level 0 Bit 8, Bit 9, Bit 10 0000 0000 0000 0000 Level 1 Bit 8 Bit 9, Bit 10 0000 0001 0000 0000 Level 2 Bit 9 Bit 8, Bit 10 0000 0010 0000 0000 Level 3 Bit 8, Bit 9 Bit 10 0000 0011 0000 0000 Level 4 Bit 10 Bit 8, Bit 9 0000 0100 0000 0000 Level 5 Bit 8, Bit 10 Bit 9 0000 0101 0000 0000