Mitsubishi — 3.4.2 Status Block

Chapter 3 Creating and Editing Screens Screen Number Status Register (SNSR) This register stores the last screen number (includes sub screen) that the user opened (refer to D11 or $26 of Table 3-4-2). Curve Control Status Register (CCSR)  Curve Sampling Status Flag When the HMI samples a trend graph or X-Y chart, the curve sampling status flag (bits 0 to 3) is turned ON. After the sampling operation is completed, the curve sampling status flag is turned OFF. Curve Sampling Flag 1 of control block corresponds to Curve Sampling Status Flag 1 of status block, Curve Sampling Flag 2 of control block corresponds to Curve Sampling Status Flag 2 of status block and vise versa.

 Curve Clear Status Flag When the HMI clears trend graph or X-Y chart, the curve clear status flag (bits 8 to 11) is turned ON. After the clear operation is completed, the curve clear status flag is turned OFF. Curve Clear Flag 1 of control block corresponds to Curve Clear Status Flag 1 of status block, Curve Clear Flag 2 of control block corresponds to Curve Clear Status Flag 2 of status block and vise versa.

3-38 Revision May, 2010 Flag Control Level Binary Display ON Level 6 Bit 9, Bit 10 Bit 8 0000 0110 0000 0000 Level 7 Bit 8, Bit 9, Bit 10 0000 0111 0000 0000 Binary Display of Relative Bit Function Position (x) 0 0000 0000 0000 000x Curve Sampling Status Flag 1 1 0000 0000 0000 00x0 Curve Sampling Status Flag 2 2 0000 0000 0000 0x00 Curve Sampling Status Flag 3 3 0000 0000 0000 x000 Curve Sampling Status Flag 4 4-7 0000 0000 xxxx 0000 Reserved 8 0000 000x 0000 0000 Curve Clear Status Flag 1 9 0000 00x0 0000 0000 Curve Clear Status Flag 2 10 0000 0x00 0000 0000 Curve Clear Status Flag 3 11 0000 x000 0000 0000 Curve Clear Status Flag 4 12-15 xxxx 0000 0000 0000 Reserved