Delta · DOP · 2 стр.
DOP Microsoft Word - .docx
Related manuals
Contents
Document text
台達地址_夾頁_20160329
Incorrect installation may result in malfunction. To ensure the HMI is well ventilated, make sure there is sufficient space between the HMI and the adjacent objects or walls. This product should be used on a case / platform which conforms to enclosure Type 4X standard (for indoor use only). The maximum panel thickness for mounting must be no greater than 5 mm. Step 2: Place the fasteners into the slots and tighten the screws until reaching the panel cutouts. Step 4: For heat dissipation, please keep a minimum clearance of 60 mm on the rear of the HMI.
Solid 24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in) Stranded 24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in) Please refer to the following diagram when wiring the power connector. The temperature rating of the cable must be greater than 75 o C (167 o F). Type Wire gauge (AWG) Stripped length Torque Step 1: Put the waterproof gasket into the HMI and then insert the HMI into the panel cutout. Step 3: Tighten the screws with the torque less than 0.5 N-M / 0.7 N-M to avoid damage to the plastic case. DOP-103BQ torque: 4.41 lb-inch (0.5 N-M) (5) Installation and wiring Installation steps: Precautions: Wiring: A USB slave B USB host A (24 AWG wire min.) D COM1 (4) Mounting dimensions Operation temperature:
0 o C to 50 o C (32 o F to 122 o F) Storage temperature: -20 o C to 60 o C (-4 o F to 140 o F) C Power input terminal (3) Description of each part DOP-103BQ (front view) DOP-103BQ (rear view) DOP-103BQ Thank you for purchasing this product. This instruction sheet provides information about the DOP-100 series HMI. Before using this product, please read through this instruction sheet carefully to ensure the correct use of the product. Please keep this sheet handy for quick reference whenever needed. Before finishing reading this sheet, please follow the instructions below: Install the product in an indoor location, which is free of vapor, corrosive and inflammable gas and liquids.
Please refer to the wiring diagram when connecting the wires. Ensure your HMI is correctly grounded. The grounding method must comply with the national electrical standard (please refer to NFPA 70: National Electrical Code, 2005 Ed.). Do not disassemble the HMI or change the wiring when power is on. Do not touch the power supply when power is on, or it may cause electric shock. When the HMI displays a low power notification and requires a battery change, please contact your local distributor or Delta Customer Service Center for the replacement. Do not change the batteries by yourself. This product can be used with other industrial automation equipment.
Please read through this sheet carefully and install the product according to the instructions to avoid danger. Cleaning method: please use a dry cloth to clean the product. This product must be used at an altitude below 2,000 m. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. For repair and maintenance, please contact Delta Electronics, Inc. Address: No.18, Xinglong Rd., Taoyuan City, Taiwan. TEL: +886-3-3626301. If you have any inquiry during operation, please contact our local distributors or Delta sales representatives. The content of this instruction sheet may be revised without prior notice.
Please consult our distributors or download the latest version at Delta’s website (http://www.delta.com.tw/ia). COM1 COM2 COM1 COM2 COM1 COM2 RS-232 RS-485 RS-485 RS-485 RS-232 RS-422 1 - - D+ - - TXD+ 2 RXD - - - RXD - 3 TXD - - - TXD - 4 - D+ - D+ - RXD+ 6 - - D- - - TXD- 7 RTS - - - RTS - 8 CTS - - - CTS - 9 - D- - D- - RXD- High color ‧ Wide screen ‧ User-friendly Delta Electronics Inc, No.18, Xinglong Rd., Taoyuan City 33068, Taiwan Instruction Sheet MODE1 MODE2 MODE3 5 GND GND GND (2) Communication port pin assignment Note: mark “-” means connection is not required.
DOP- 103BQ (1) General precautions COM Port Pin DOP-103BQ COM port A Operation / display area A USB slave B USB host C Power input terminal D COM1 (24 AWG wire min.) MODE1 MODE2 MODE3 COM Port Pin COM1 COM2 COM1 COM2 COM1 COM2 RS-232 RS-485 RS-485 RS-485 RS-232 RS-422 1 - - D+ - - TXD+ 2 RXD - - - RXD - 3 TXD - - - TXD - 4 - D+ - D+ - RXD+ 5 GND GND GND 6 - - D- - - TXD- 7 RTS - - - RTS - 8 CTS - - - CTS - 9 - D- - D- - RXD- Type Wire gauge (AWG) Stripped length Torque Solid 24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in) Stranded 24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in)
台達地址_夾頁_20160329
Approvals CE / UL (please use shielding network cable and magnetic ring with the filter of Supplied by Class 2 or SELV circuit (isolated from MAINS by double insulation) Vibration resistance Conforms to IEC61131-2: continuous vibration 5 Hz - 8.3 Hz with amplitude Note: 1. The half-life of the backlight is defined as the maximum luminance being reduced by 50% when the maximum drive current is supplied to the HMI. The life of LED backlight shown here is estimated at the room temperature of 25 o C with ambient humidity. 2. The withstand voltage of the isolated power circuit is 1500V peak for 1 minute. 3.
The HMI power consumption is the power consumed when the HMI is not connecting with other peripheral devices. To ensure normal operation of the HMI, the recommended capacity of the power supply is 1.5 to 2 times of the specified power consumption. 4. Isolated power supply is recommended. 5. For DOPSoft programming software for DOP-100 series and the user manual, you can download them at http://www.delta.com.tw/ia. Backlight LED backlight (half-life under room temperature 25 o C > 20,000 hours) * 1 Operation voltage *2 DC +24V (-15% to +15%) (please use an isolated power supply) Leakage current 500 V AC for 1 minute (between DC24V terminal and FG terminal) 6.
DOP-100 series can be used with other industrial automation equipment. Please read through this sheet carefully and install the product according to the instructions to avoid danger.
Operating environment 10% to 90% RH [0 o C - 40 o C], 10% to 55% RH [41 o C - 50 o C]; 11 ms, 15 G Peak, in X, Y, Z directions each for 6 times Touchscreen 4-wire resistive touchscreen > 1,000,000 operated Buzzer Multi-tone frequency (2 K – 4 KHz) / 80 dB COM1 RS-232 (supporting flow control) / RS-485 *2 (subject to operation temperature and condition) 3.5 mm; 8.3 Hz - 150 Hz with amplitude 1G USB 1 USB slave Ver 2.0; 1 USB host Ver 2.0 Backup battery 3V lithium battery CR2032 Ч 1 Backup battery life About 3 years or more at 25 o C Storage temperature -20 o C to +60 o C (-4 o F to 140 o F) Shock resistance Conforms to IEC60068-2-27:
Panel type 4.3" TFT LCD (65535 colors) Display range 95.04 x 53.856 mm CPU ARM Cortex-A8 (800 MHz) COM2 RS-422 / RS-485 *2 300 ohm / 100 MHz) Operation temperature 0 o C to 50 o C (32 o F to 122 o F) pollution degree: 2 Model DOP-103BQ Resolution 480 x 272 pixels Brightness 400 cd/mІ (Typ.) Flash ROM 256 Mbytes RAM 256 Mbytes Cooling method Natural cooling Panel waterproof level IP65 / NEMA 4 Power consumption *2 5.67W (Max) *3 (W) x (H) x (D) mm 137 x 103 x 37.1 (W) x (H) mm 118.8 x 92.8 Weight Approx.
280g Network interface N/A SD N/A COM3 N/A Auxiliary function key N/A Calendar Built-in (6) Hardware specifications Mounting dimension communication Dimension Serial port Display Model DOP-103BQ Display Panel type 4.3" TFT LCD (65535 colors) Resolution 480 x 272 pixels Backlight LED backlight (half-life under room temperature 25oC > 20,000 hours) *1 Display range 95.04 x 53.856 mm Brightness 400 cd/m² (Typ.) CPU ARM Cortex-A8 (800 MHz) Flash ROM 256 Mbytes RAM 256 Mbytes Touchscreen 4-wire resistive touchscreen > 1,000,000 operated Buzzer Multi-tone frequency (2 K – 4 KHz) / 80 dB Network interface N/A USB 1 USB slave Ver 2.0; 1 USB host Ver 2.0 SD N/A RS-232 (supporting flow control) / RS-485*2 COM1 Serial RS-422 / RS-485*2 communication COM2 port COM3 N/A Auxiliary function key N/A Calendar Built-in Cooling method Natural cooling CE / UL (please use shielding network cable and magnetic ring with the filter of Approvals 300 ohm / 100 MHz) Panel waterproof level IP65 / NEMA 4 DC +24V (-15% to +15%) (please use an isolated power supply) Operation voltage*2 Supplied by Class 2 or SELV circuit (isolated from MAINS by double insulation) Leakage current 500 V for 1 minute (between DC24V terminal and FG terminal) AC Power consumption*2 5.67W (Max) *3 Backup battery 3V lithium battery CR2032 × 1 About 3 years or more at 25oC Backup battery life (subject to operation temperature and condition) Operation temperature 0oC to 50oC (32oF to 122oF) Storage temperature -20oC to +60oC (-4oF to 140oF) 10% to 90% RH [0oC - 40oC], 10% to 55% RH [41oC - 50oC]; Operating environment pollution degree:
2 Conforms to IEC61131-2: continuous vibration 5 Hz - 8.3 Hz with amplitude Vibration resistance 3.5 mm; 8.3 Hz - 150 Hz with amplitude 1G Conforms to IEC60068-2-27: Shock resistance 11 ms, 15 G Peak, in X, Y, Z directions each for 6 times Dimension 137 x 103 x 37.1 (W) x (H) x (D) mm Mounting dimension 118.8 x 92.8 (W) x (H) mm Weight Approx. 280g