Delta DVP-ES2 — 3.2 Explanations to Basic Instructions

3. Instruction Set Note: MC-MCR master-control instruction supports max 8 layers of nest levels. Please use the instructions in order from N0~ N7. Program example: Ladder diagram: Instruction: Operation: LD X0 Load NO contact X0 LD X1 Load NO contact X1 OUT Y0 Drive coil Y1 : LD X2 Load NO contact X2 LD X3 Load NO contact X3 OUT Y1 Drive coil Y1 : : : LD X10 Load NO contact X10 LD X11 Load NO contact X11 OUT Y10 Drive coil Y10 : END instruction needs to be connected at the end of program. PLC will scan from address 0 to Explanations: END instruction and return to address 0 to scan again. Explanation: NOP instruction does not conduct any operations in the program, i.e.

the operation result remains the same after NOP is executed. Generally NOP is used for replacing certain instruction without altering original program length. 3-11 MC N0 X1 Y0 X2 MC N1 X3 Y1 MCR N1 MCR N0 X10 MC N0 X11 Y10 MCR N0 MC N0 MCR N0 MC N0 Enable N0 nest level MC N1 MC N1 Enable N1 nest level MCR N1 MCR N0 MCR N1 Reset N1 nest level MC N0 MCR N0 Reset N0 nest level MC N0 Enable N0 nest level MCR N0 Reset N0 nest level Mnemonic Function Program steps Controllers SA2 ES2/EX2 SS2 SX2 SE END Program End 1 SA2 ES2/EX2 SS2 SE Mnemonic Function Program steps Controllers SA2 ES2/EX2 SS2 SX2 SE Controllers NOP No operation 1 SA2 ES2/EX2 SS2 SX2 SE