Delta DVP-ES2 — 3.2 Explanations to Basic Instructions

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming Program example: Ladder Diagram: Instruction: Operation: NOP instruction will be omitted in the ladder diagram LD X0 Load NO contact X0 NOP No operation OUT Y1 Drive coil Y1 Explanation: When the conditions preceding NP command change from false to true, NP command (works as contact A) will be ON for a scan cycle. In the next scan cycle it turns OFF. Program Example: Ladder Diagram: Instruction: Operation: LD M0 Load NO contact M0 M0 M1 Y0 P AND M1 Connect NO contact M1 in series NP Negative contact to Positive contact Timing Diagram: OUT Y0 Drive coil Y0 M0 M1 A scan cycle A scan cycle Y0 Explanation:

When the conditions preceding PN command change from true to false, PN command (works as contact A) will be ON for a scan cycle. In the next scan cycle it turns OFF. Program Example: Ladder Diagram: Instruction: Operation: LD M0 Load NO contact M0 AND M1 Connect NO contact M1 in series M0 M1 PN Negative contact to Positive contact OUT Y0 Drive coil Y0 3-12 0 NOP Y1 NOP Mnemonic Function Program steps Controllers SA2 ES2/EX2 SS2 SX2 SE Controllers NP Negative contact to Positive contact 1 SA2 ES2/EX2 SS2 SX2 SE Mnemonic Function Program steps Controllers PN Positive contact to Negative contact 1 SA2 ES2/EX2 SS2 SX2 SE P Y0 P