Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set Program example 1: 1. When M1168 = OFF (in BCD mode) and X0 = ON, the 4 th (thousand) and 3 rd (hundred) digit of the decimal value in D10 start to move to the 3 rd (hundred) and 2 nd (ten) digit of the decimal 2. When the BCD value exceeds the range of 0 ~ 9,999, PLC detects an operation error and will value in D20. 10 3 and 10 0 of D20 remain unchanged after this instruction is executed. not execute the instruction. M1067, M1068 = ON and D1067 stores the error code OE18 (hex).

M1001 M1168 X0 D10(BIN 16bit) Auto conversion D10(BCD 4 digits) Shift move D20(BCD 4 digits) Auto conversion D20(BIN 16bit) If D10 = K1234, D20 = K5678 before execution, D10 remains unchanged and D20 = K5128 after execution. Program example 2: When M1168 = ON (in BIN mode) and SMOV instruction is in use, D10 and D20 will not be converted in BCD format but be moved in BIN format (4 digits as a unit). M1000 M1168 X0 Digit 4 Digit 3 Digit 2 Digit 1 D10(BIN 16bit) Shift move Digit 4 Digit 3 Digit 2 Digit 1 D20(BIN 16bit) No variation No variation If D10 = H1234, D20 = H5678 before execution, D10 remains unchanged and D20 = H5128 after execution.

3-63 SMOV D10 K4 K2 D20 K3 103 102 101 100 o variation No variatio 103 102 101 100 SMOV D10 K4 K2 D20 K3