3. Instruction Set API 30 Operands: D : Device to be rotated n : Number of bits to be rotated in 1 rotation Explanations: 2. The status of the last bit rotated (marked with ※ ) is copied to the carry flag M1022 (Carry flag) 1. This instruction rotates bit status of the device D to the right for n bits 3. This instruction is generally used in pulse execution mode (RORP, DRORP). 4. If operand D uses index F, only a 16-bit instruction is available. 5. If operand D is specified as KnY, KnM or KnS, only K4 (16-bit) or K8 (32-bit) is valid. 6. Valid range of operand n : 1≤ n ≤16 (16-bit), 1≤ n ≤32 (32-bit) Program Example:
When X0 goes from OFF to ON, the 16 bits (4 bits as a group) in D10 will rotate to the right, as shown in the figure below. The bit marked with ※ will be sent to carry flag M1022.. X0 Rotate to the right Upper bit Lower bit M1022 Carry flag D10 16 bits Upper bit lower bit After one rotation to the right D10 M1022 M1022 0 Carry flag * 3-91 Mnemonic Operands Function Controllers SA2 ES2/EX2 SS2 SX2 SE Controllers D ROR P Rotation Right ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F ROR, RORP: 5 steps DROR, DRORP:
9 steps D * * * * * * * * n * * PULSE 16-bit 32-bit SA2 SX2 SS2 SA2 SA2 SX2 ES2/EX2 SS2 ES2/EX2 SX2 ES2/EX2 SS2 SE SE SE RORP D10 K4 0 1 1 1 1 0 1 1 0 1 0 0 0 1 0 1 0 1 0 1 0 1 1 1 1 0 1 1 0 1 0 0