Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming Registers for data to be sent (sending messages) Registers for received data (responding messages) 2. M1177 = ON, other Delta VFDs are supoported a) S 1 = Address of VFD-A. Range of S 1 : K0 ~ K255, when S 1 is specified as K0, PLC will broadcast to all connected VFDs. b) S 2 = Running frequency of VFD. Please refer to manuals of specific VFD. In STOP instruction, operand S 2 is reserved. c) n = Operation mode.  In FWD instruction: n = 0  Forward mode; n = 1  Forward JOG. Other values will be regarded as normal forward mode.  In REV instruction: n = 0  Reverse mode; n = 1  Reverse JOG.

Other values will be regarded as normal reverse mode  In STOP instruction: operand n is reserved. d) When Forward JOG is selected in FWR instruction, set value in S 2 is invalid. If users need to modify the JOG frequency, please refer to manuals of specific VFDs. Program Example: COM2 (RS-485) Communication between PLC and VFD-B series inverter (ASCII Mode, M1143 = OFF), Retry when communication time-out occurs.

3-298 Register Data Descriptions D1089 low ‘C’ 43 H Header of control string D1090 low ‘♥’ 03 H Checksum D1091 low ‘’ 01 H Command acknowledgement (communication mode) D1092 low ‘0’ 30 H Communication address D1093 low ‘0’ 30 H D1094 low ‘0’ 30 H D1095 low ‘1’ 31 H D1096 low ‘0’ 30 H Operation command D1097 low ‘5’ 35 H D1098 low ‘0’ 30 H D1099 low ‘0’ 30 H Register DATA Explanation D1070 low ‘C’ 43 H Header of control string D1071 low ‘♥’ 03 H Checksum D1072 low ‘♠’ 06 H Acknowledge back. (Check feedback data) (correct: 06H, Error:

07 H) D1073 low ‘0’ 30 H Communication address D1074 low ‘0’ 30 H D1075 low ‘0’ 30 H D1076 low ‘1’ 31 H D1077 low ‘0’ 30 H Operation command D1078 low ‘5’ 35 H D1079 low ‘0’ 30 H D1080 low ‘0’ 30 H