3. Instruction Set Operands: S 1 : Lower bound of the random number S 2 : Upper bound of the random number D : Operation result Explanations: 1. The range of 16-bit operands S 1 , S 2 : K0 ≦ S 1 , S 2 K ≦ 32,767; the range of 32-bit operands S 1 , S 2 : K0 ≦ S 1 , S 2 K2,147,483,647. ≦ 2. Entering S 1 > S 2 will result in operation error. The instruction will not be executed at this time, M1067, M1068 = ON and D1067 records the error code 0E1A (HEX) Program Example: When X10 = ON, RAND will produce the random number between the lower bound D0 and upper bound D10 and store the result in D20.
3-393 API Mnemonic Operands Function Controllers 154 D RAND P Random number ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F RAND, RANDP: 7 steps DRAND, DRANDP: 13 steps S 1 * * * * * * * * * * * S 2 * * * * * * * * * * * D * * * * * * * * PULSE 16-bit 32-bit SS2 SA2 SA2 SA2 ES2/EX2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE X RAND D0 D10 D20