DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming API 155 Operands: S : Input signal from servo (occupies 3 consecutive devices) D 1 : Control signal for controlling servo (occupies 3 consecutive devices at most) D 2 : Absolute position data (32-bit) read from servo (occupies 4 consecutive devices at most) Explanations: (The instruction can be used in DVP-ES2/EX2 series PLCs whose version is 3.00/DVP-SA2 series PLCs whose version is 2.40/DVP-SE series PLCs whose version is 1.20/DVP-SX2 series PLCs whose version is 2.20/DVP-SS2 series PLCs (and below).) 1. This instruction reads the absolute position (ABS) of servo drive with absolute position check function, e.g. MITSUBISHI MR-J2.
2. Only 32-bit instruction is applicable for ABSR instruction (DABSR) and it can only be used ONCE in the program. 3. S : input signal from servo. 3 consecutive devices S , S +1, S +2 are occupied. S and S +1 are connected to the ABS (bit0, bit1) of servo for data transmitting. S +2 is connected to servo for indicating transmission data being prepared. 4. D 1 : control signal for controlling servo. 3 consecutive devices D 1 , D 1 +1, D 1 +2 are occupied. D 1 is connected to servo ON (SON) of servo, D 1 +1 is connected to ABS transmission mode of servo and D 1 +2 is connected to ABS request.
3-394 Mnemonic Operands Function Controllers D ABSR Absolute position read ES2/EX2 SS2 SA2 SX2 SE Typ e OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F DABSR: 13 steps S * * * * D 1 * * * D 2 * * * * * * * PULSE 16-bit 32-bit SA2 SA2 SA2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE