Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set 5. D 2 : Absolute position data (32-bit) read from servo. 2 consecutive devices D 2 , D 2 +1 are 6. When DABSR instruction is completed, M1029 will be ON. M1029 has to be reset by users. occupied. D 2 is low word and D 2 +1 is high word. 7. Please use NO contact as the drive contact of DABSR instruction. If the drive contact is OFF during the execution of DABSR, the instruction will be stopped and errors will occur on read data. 8. If the drive contact of DABSR instruction turns OFF after the instruction is completed, the servo ON (SON) signal connected to D 1 will also turn OFF and the operation will be disabled. Explanations:

(The instruction can be used in DVP-ES2/EX2 series PLCs whose version is 3.20/DVP-SA2 series PLCs whose version is 2.60/DVP-SE series PLCs whose version is 1.40/DVP-SX2 series PLCs whose version is 2.40 (and above).) 1. This instruction reads the absolute position (ABS) of MITSUBISHI MR-J2 servo drive (with absolute position check function), and the absolute position (ABS) of Delta ASDA-A2 servo drive (whose firmware version is 1.045 sub12 (and above). 2. The state of M1177 determines the servo drive which is used. If M1177 is Off, MITSUBISHI MR-J2 servo drive is used. Please refer to the points above for more information about setting MITSUBISHI MR-J2 servo drive.

If M1177 is On, Delta ASDA-A2 servo drive is used. Please refer to the points below for more information about settiing Delta ASDA-A2 servo drive. 3. Only 32-bit instruction is applicable for ABSR instruction (DABSR) and it can only be used ONCE in the program. 4. The input signal from a servo is stored in S . S occupies 3 consecutive devices. S , S +1, and S 5. D 1 will occupy 2 consecutive devices, D 1 , and D 1 + 1. D 1 is connected to ABSE on a servo. +2 are connected to ABSR, ABSD, ABSW on a servo. D 1 +1 is connected to ABSQ on a servo. Please refer to the example below for more information about wiring.

3-395 PLC DVP32ES200T S UP S X X X D1 Y Y Y Z CN1B 0 VDD /S ABS(bit 0) 0 D01 ABS(bit 1) 1 ZSP Transmission ready 2 TLC SERVO ON 4 SON ABS transmission mode SERVO AMP MR-J2-A 3 4 19 6 5 8 9 10 Y 4 SON 5 ABS transmission mode Y 5 ABS request ABSM 8 Y 6 ABSR 9 Z P0 SG 10 UP 0 S /S X 0 X 1 X 2 VDD 3 D01 4 ZSP 19 TLC 6