Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 6. D 2 will occupy 4 consecutive devices D 2 , D 2 +1. D 2 +2, and D 2 +3. The absolute acoordinate stored in D 2 +1. The lower 16 bits of the encoder absolute position (pulse number within system status (P0-50) is stored in D 2 , the encoder absolute position (multiturn) (P0-51) is singleturn or PUU) (P0-52) is stored in D 2 +2. The higher 16 bits of the encoder absolute position (pulse number within singleturn or PUU) (P0-52) is stored in D 2 +3. 7. After the the reading of the absolute positio of a servo through the instruciton DABSR is complete, M1580 will be On.

If an error occurs during the execution of the instruciton, M1581 will be On. 8. When driving the DABSR command, please specify normally open contact. If the drive contact of DABSR command turns Off when DABSR command read starts, the execution of absolute current value read will be interrupted and result in incorrect data. Please be careful and notice 9. If the input signals are from the high-speed input points X0~X7, it takes 2 seconds for the that. instruction to be executed. if the input signals are form the input points following X10, it takes 2.5 seconds for the instruciton to be executed. The time it takes for the instruction to be executed is affected by the scan time.

Program Example: (for DVP-ES2/EX2 series PLCs whose version is 3.00/DVP-SA2 series PLCs whose version is 2.40/DVP-SE series PLCs whose version is 1.20/DVP-SX2 series PLCs whose veresion is 2.20/DVP-SS2 series PLCs (and below)) 1. When X7 = ON, the 32-bit absolute position data read from Mitsubishi MR-J2 servo will be stored in the registers D0~D1. At the same time, timer T0 is enabled and starts to count for 5 seconds. If the 32-bit instruction is not completed within 5 seconds, M10 will be ON, indicating operation errors. 2. When enabling the connection to the system, please synchronize the power input of DVP-PLC and SERVO AMP or activate the power of SERVO AMP earlier than DVP-PLC.

3-396 PLC DVP32ES200T S U S X X X D1 Y Y Z CN1 P0 VDD /S ABSR 0 DO2+ ABSD 1 DO3+ ABSW 2 DOx+ ABSE 4 DIx- ABSQ SERVO DRIVE ASDA-A2 17 5 3 8 9 Y 4 DIx- ABSQ Y 5 DI4- 8 Z P0 COM- 9 U P0 S /S X 0 X 1 X 2 VDD 17 DO2+ 5 DO3+ 3 DOx+