Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set API 178 Operands: S : Start device for input parameters D : Start device for output parameters Explanations: 1. This instruction is a function provided for free. It is for non-commercial use only. If users want to use the instruction for a commercial purpose, they have to obtain permission from related organizations before they sell equipment. 2. Operand S occupies 208 consecutive word registers. The function of each device is as below: 3-435 Mnemonic Operands Function Controllers D SPA Solar Panel Positioning ES2/ EX2 SS2 SA2 SX2 SE Typ e OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F DSPA:

9 steps S * * * D * PULSE 16-bit 32-bit ES2/ EX2 SS2 SA2 SX2 SE ES2/ EX2 SS2 SA2 SX2 SE ES2/ SE SS2 SA2 SX2 EX2 No. Content Range Format Note S + 0 Year 2000 ~ Word Please enter the correct time of the local longitude. Please refer to DTM (parameter 11) for the conversion formula. A simple illustration is as in point 6. S + 1 Month 1 ~ 12 Word S + 2 Day 1 ~ 31 Word S + 3 Hour 0 ~ 23 Word S + 4 Minute 0 ~ 59 Word S + 5 Second 0 ~ 59 Word S + 6~7 Time difference (Δt) (sec) ± 8000 Float S + 8~9 Local time zone ± 12 Float West: negative S + 10~11 Longitude ± 180 Float West: negative Unit: degree S + 12~13 Latitude ± 90 Float South: negative Unit: degree S + 14~15 Elevation 0~ 6500000 Float Unit:

meter S + 16~17 Pressure 0 ~ 5000 Float Unit: millibar S + 18~19 Mean annual temperature (MAT) -273~6000 Float Unit: °C S + 20~21 Slope ± 360 Float S + 22~23 Azimuth ± 360 Float S + 24~25 Atmospheric refraction between sunrise and sunset ± 5 Float S +26~207 Reserved for system operation