Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 3. Operand D occupies 8 consecutive word registers. The function of each device is as below: 4. The execution time of SPA instruction costs up to 50ms, therefore we suggest users to execute this instruction with an interval not less than 1 sec, preventing the instruction from taking too much PLC operation time. 5. Definition of Zenith: 0° and 45°. 0° 45° 6. Definition of Azimuth: N N 0° 0° 270° 270° 90° 90° 180° 180° 7. The correct time of the local longitude: If we suppose that it is AM8:00:00 in Taipei, and the longitude is 121.55 degrees east, then the correct time of the local longitude in Taipei should be AM8:06:12.

Please refer to API168 DTM instruction (parameter k11) for more explanation. 3-436 No. Content Range Format Note D + 0~1 Zenith 0 ~ 90 Float Horizontal=0 D + 2~3 Azimuth 0 ~ 360 Float North point=0 D + 4~5 Incidence 0 ~ 90 Float D + 6 Converted DA value of Zenith 0 ~ 2000 Word 1LSB = 0.045 degree D + 7 Converted DA value of Azimuth 0 ~ 2000 Word 1LSB = 0.18 degree