DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming API 193 Operands: setting D: Pulse output device S1: Number of output pulses of X axis S2: Number of output pulses of Y axis S: Parameter Explanations: 1. For ES2/EX2 models, only V1.20 or above supports the function. 2. The instruction only supports the pulse output type: Pulse / Direction. 3. S 1 and S 2 specify the number of output pulses (relative positioning) on X axis (Y0) and Y axis (Y2). Range: -2,147,483,648 ~ +2,147,483,647 (The “+/-“ sign indicates the forward/backward direction). In forward direction, the present value of pulse output on CH0 (D1031 High, D1030 low), CH1 (D1337 high, D1336 low) increases.
In reverse direction pulse output, value in (D1031, D1330) and (D1336, D1337) decreases. 4. The low word of S (settings of direction and resolution): K0 refers to clockwise 20-segment output; K1 refers to counterclockwise 20-segment output; A 90 arc can be drawn (see figure 1 and 2). 5. The high word of S (settings of motion time, unit: 0.1sec): Setting range: K2 ~ K200 (0.2 sec. ~ 20 secs.) This instruction is restricted by the maximum pulse output frequency; therefore when the set time is faster than the actual output time, the set time will be automatically modified.
Y Y X X Figure 1 Figure 2 3-462 Mnemonic Operands Function 2-Axis Relative Position Arc Interpolation Controllers ES2/EX2 SS2 SA2 SX2 SE D CIMR Controllers ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F DCIMR: 17 steps S 1 * * * S 2 * * * S * D * 16-bit 32-bit SA2 SA2 SA2 SS2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE (S ,S ) 1 2 02 stnemges 0,0) 20 segments (S ,S ) 1 2 20 segments 02 stnemges (0,0) 20 segments