Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set API 194 Operands: Parameter setting D: Pulse output device S1: Number of output pulses of X axis S2: Number of output pulses of Y axis S: Explanations: 1. For ES2/EX2 models, only V1.20 or above supports the function. 2. The instruction only supports the pulse output type: Pulse / Direction. 3. S 1 and S 2 specify the number of output pulses (absolute positioning) on X axis (Y0) and Y axis (Y2). Range: -2,147,483,648 ~ +2,147,483,647. When S 1 and S 2 are bigger than PV of pulse output in CH0 (D1031 High, D1030 low) / CH1 (D1337 high, D1336 low), pulse output will operate in positive direction and the direction signal output Y1, Y3 will be OFF.

When S 1 and S 2 are smaller than PV of pulse output, pulse output will operate in negative direction and the 4. For the rest of the explanations on the instruction, special D and special M, please refer to API direction signal output Y1, Y3 will be ON. 193 DCIMR instruction. Program Example 1: 1. Draw an ellipse as the figure below. Y ) ) 32000,0 ( 0,0 X 2. Steps: a) Set the four coordinates (0,0), (16000, 22000), (32000, 0), (16000, -22000) (as the figure above).

Place them in the 32-bit registers (D200, D202), (D204, D206), (D208, D210), 3-467 Mnemonic Operands Function 2-Axis Absolute Position Arc Interpolation Controllers ES2/EX2 SS2 SA2 SX2 SE D CIMA Controllers ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F DCIMA: 17 steps S 1 * * * S 2 * * * S * D * PULSE 16-bit 32-bit SA2 SA2 SA2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE (16000,220 ( (16000,-22