DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 203 Operands: S 1 : Source value S 2 : Parameters D : Operation result Explanations: 1. SCLP instruction performs a proportional calculation according to the internal slope equation as well as the parameters set in this instruction. 2. Settings of S 2 for 16-bit instruction (occupies 4 consecutive devices): 3. Settings of S 2 for 32-bit instruction (occupies 8 consecutive devices). 4. Operation equation in the instruction: D = [( S 1 – min. source value) Ч (max. destination value – 5. The equation to obtain the operation equation of the instruction: min. destination value)] ч (max. source value – min. source value) + min.
destination value y = kx + b where y = Destination value ( D ) k = Slope = (max. destination value – min. destination value) ч (max. source value – min. source value) x = Source value ( S 1 ) b = Offset = Min. destination value – Min. source value Ч slope 6. Substitute the above parameters into y = kx + b and the operation instruction can be obtained. y = kx + b = D = k S 1 + b = slope Ч S 1 + offset = slope Ч S 1 + min. destination value – min. source 3-488 Mnemonic Operands Function Parameter proportional calculation Controllers D SCLP P ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F SCLP, SCLPP: 7 steps DSCLP, DSCLPP:
13 steps S 1 * * * S 2 * D * 16-bit 32-bit SS2 SA2 SA SE 2 SX2 ES2/EX SA2 SX2 ES2/EX2 SS2 SS2 SX2 SE 2 SE Device No. Parameter Range S 2 Max. source value -32768~32767 S 2+1 Min. source value -32768~32767 S 2+2 Max. destination value -32768~32767 S 2+3 Min. destination value -32768~32767 Range Device No. Parameter Integer Floating point number S 2、S 2+1 Max. source value -2,147,483,648~2,147,483,647 Range of 32-bit floating point number S 2+2、3 Min. source value S 2+4、5 Max. destination value S 2+6、7 Min. destination value