Delta DVP-ES2 — 2.13 Special Data Register

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 2-32 OFF STOP RUN Special ES2 SA2 Latch Content SS2 SX2    Attrib. Default D EX2 SE -ed ON RUN STOP occurrence D1010* Current scan time (Unit: 0.1ms) ○ ○ ○ ○ # # # R NO 0 D1011* Minimum scan time (Unit: 0.1ms) ○ ○ ○ ○ # # # R NO 0 D1012* Maximum scan time (Unit: 0.1ms) ○ ○ ○ ○ # # # R NO 0 D1015* Value of accumulative high-speed timer (0~32,767, unit: 0.1ms) ○ ○ ○ ○ 0 - - R/W NO 0 D1018* πPI (Low byte) ○ ○ ○ ○ H’ 0FDB H’ 0FDB H’ 0FDB R/W NO H’ 0FDB D1019* πPI(High byte) ○ ○ ○ ○ H’ 4049 H’ 4049 H’ 4049 R/W NO H’ 4049 D1020* X0~X7 input filter (unit:

ms) 0~20ms adjustable ○ ○ ○ ○ 10 - - R/W NO 10 D1021* X10~X17 X7 input filter (unit: ms) 0~20ms adjustable (available for 28SS2: V3.42, 28SA2: V3.0, 26SE: V2.0 and later) ╳ ○ ○ ╳ 10 - - R/W NO 10 D1022 Counting mode selection (Double frequency/ 4 times frequency) for AB phase counter (From X0, X1 input) ○ ○ ○ ○ 4 - - R/W NO 4 D1023* Register for Storing detected pulse width (unit:

0.1ms) ○ ○ ○ ○ 0 - - R/W NO 0 D1025* Code for communication request error ○ ○ ○ ○ 0 - - R NO 0 D1026* The pulse number for masking Y0 is set when M1156 = ON (Low word) ○ ○ ○ ○ 0 0 - R/W NO 0 D1027* The pulse number for masking Y0 is set when M1156 = ON (High word) If the value in the 32-bit register (D1027, D1026) is less than or equal to 0, the function will not be enabled. (Default value:

0) ○ ○ ○ ○ 0 0 - R/W NO 0 D1028 Index register E0 ○ ○ ○ ○ 0 - - R/W NO 0 D1029 Index register F0 ○ ○ ○ ○ 0 - - R/W NO 0 D1030 PV of Y0 pulse output (Low word) ○ ○ ○ ○ - - - R/W YES 0 D1031 PV of Y0 pulse output (High word) ○ ○ ○ ○ - - - R/W YES 0 D1032 PV of Y1 pulse output (Low word) ○ ○ ○ ○ 0 - - R/W NO 0 D1033 PV of Y1 pulse output (High word) ○ ○ ○ ○ 0 - - R/W NO 0 D1036* COM1 (RS-232) communication protocol ○ ○ ○ ○ H’86 - - R/W NO H’86 D1037* Register for setting 8-sets SPD function (has to be used with M1037) ○ ○ ○ ○ 0 - - R/W NO 0 D1038 1. Delay time setting for data response when PLC is SLAVE in COM2 / COM3 RS- 485 communication. Range: 0 ~ 10,000 (unit: 0.1ms). 2.

By using PLC LINK in COM2 (RS-485), D1038 can be set to send next communication data with delay. Range: 0 ~ 10,000 (Unit: one scan cycle) ○ ○ ○ ○ - - - R/W NO 0 D1039* Fixed scan time (ms) ○ ○ ○ ○ 0 - - R/W NO 0 D1040 No. of the 1st step point which is ON. ○ ○ ○ ○ 0 - - R NO 0 D1041 No. of the 2nd step point which is ON ○ ○ ○ ○ 0 - - R NO 0 D1042 No. of the 3rd step point which is ON. ○ ○ ○ ○ 0 - - R NO 0 D1043 No. of the 4th step point which is ON ○ ○ ○ ○ 0 - - R NO 0 D1044 No. of the 5th step point which is ON. ○ ○ ○ ○ 0 - - R NO 0 D1045 No. of the 6th step point which is ON ○ ○ ○ ○ 0 - - R NO 0 D1046 No. of the 7th step point which is ON. ○ ○ ○ ○ 0 - - R NO 0 D1047 No.

of the 8th step point which is ON ○ ○ ○ ○ 0 - - R NO 0 D1049 No. of alarm which is ON ○ ○ ○ ○ 0 - - R NO 0 D1050 ↓ D1055 Processing MODRD communication data The PLC automatically converts the data in D1070~D1085 in the ASCII mode into hexadecimal values, or combines two lower 8 bits in the RTU mode into 16 bits in the RTU mode. ○ ○ ○ ○ 0 - - R NO 0 D1056* Low word of X0’s input pulse frequency (Unit: 0.001Hz) It is used with M1357. V3.22 ╳ ╳ V2.66 0 0 - R NO 0