Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming Operands S 1 : Station address of servo S 2 : Relative target position S 3 : Target speed Explanation 1. The INITC and ASDON (servo ON) instructions must be complete before this instruction is executed. 2. It is not available for pulse type instructions. Do not use pulse type contact. 3. The range of S 1 is K1–K8 (for servo). There will be no execution when the input value is out of the range. 4. The range of S 2 is -2147483648 to +2147483647. The +/- sign indicates the forward / reverse direction. The target position is a relative position. 5. For firmware V3.48 or earlier versions, this function is only available for ASDA-A2.

The unit of the value of S 3 is 0.1 rpm. The range is 1–60000, which indicates 0.1–6000.0 rpm. 6. For firmware V3.60 or later, this function is only available for ASDA-A3. When using rotary motor, the unit of the value of S 3 is 0.1 rpm. The range is 1–60000, which indicates 0.1–6000.0 rpm. When using linear motor, the unit of the value of S 3 is 10 -6 m/s. The range is 1-15999999, which indicates 0.000001-15.999999 m/s. 7. You need to use CASD instruction for acceleration and deceleration. 8. Once the target position is reached, the corresponding completion flags of axes M1624-M1631 will be set to ON.

3-548 Mnemonic Operands Function Controllers ES2-C D DRVIC S 1,S 2,S 3 Servo relative position control Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F DDRVIC: 13 steps S 1 * * S 2 * * * S 3 * * * PULSE 16-bit 32-bit ES2-C